GE Multilin M60 Motor Protection System H-3
APPENDIX H H.1 CHANGE NOTES
H
1-1 1-1 Update Updated Figure 1-1 Rear Nameplate
3-8 3-8 Update Updated Figure 3-10 Rear Terminal View
Table H–6: MAJOR UPDATES FOR M60 MANUAL REVISION Y1 (Sheet 1 of 2)
PAGE
(X2)
PAGE
(Y1)
CHANGE DESCRIPTION
All All Delete Deleted content pertaining to Ethernet switch
Title Title Update Changed part numbers. Updated address and contact information.
1-1 1-1 Update Updated address and contact information
2- 2- Add Added CPU options T, U, and V to order code table
2- 2- Delete Removed E, G, H, J, S from CPU options from order code tables
2-8 2-8 Delete Deleted 9S, 2S, 2T from replacement module order code Tables 2-7 and 2-8
2-18 2-18 Update Updated Ethernet fiber table in section 2.2.8 Communications
3-10 3-10 Update Updated Figure 3-12 Typical Wiring Diagram
3-23 3-23 Update Deleted references to COM 1 RS485 port in section 3.2.9 CPU Communication Ports. Revised
text and Figure 3-24 CPU Module Communications Wiring to include only modules T, U, V in
section 3.2.9a.
5-1 5-1 Update Updated the front panel main menu to include the CyberSentry security menu
5-15 5-15 Update Update Communications main menu to remove the SNTP Protocol submenu
5-16 5-16 Delete Deleted references to COM 1 RS485 port in section 5.2.4b Serial Ports
5-16 5-16 Add Added section 5.2.4c Ethernet Network Topology
5-17 5-17 Update Updated Networks section 5.2.4d to include all three Ethernet ports
5-17 5-17 Update Added 0 as valid number to section 5.2.4e Modbus Protocol section
5-40 5- Delete Deleted Local Time Offset, Daylight Savings Time, DST (start/stop for month/day/hour) from Real
Time Clock menu
5- 5-40 Add Added submenus Precision Time Protocol, SNTP Protocol, and Local Time and Synchronizing
Source settings to Real Time Clock menu
5- 5-41 Add Added new Precision Time Protocol (1588) menu and setting descriptions
5- 5- Update Changed Communication to Real Time Clock in SNTP protocol settings path. Moved SNTP
Protocol menu and settings descriptions to Real Time Clock subsection
5-37 5- Deleted Deleted section k) SNTP Protocol and the settings descriptions
5- 5-44 Add Added new section for Local Time menu settings and settings description
5- 5-52 Add Added new PTP Fail menu item to the User-Programmable Self Tests menu
5- 5- Add Added PTP Failure and CLOCK UNSYNCHRONIZED to Flexlogic Operands table
5- 5-114 Update Added row for DeltaTime to Table 5-: FlexElement Base Units
5-231 5-231 Delete Deleted section 5.8.5c Remote Devices: ID of Device for Receiving GSSE/GOOSE Messages,
meaning the Settings > Input/Outputs > Remote Devices settings
5- 5-254 Add Added new CyberSentry security section and main menu, local passwords, session settings,
restore defaults, and supervisory subsections to Chapter 5
6-1 6-1 Update Update Actual Values main menu to include Real Time Clock Synchronization submenu
6- 6-7 Add Added new section for Real Time Clock synchronizing consisting of the menu of settings and the
setting descriptions
6-11 6-11 Delete Deleted section 6.2.20 Ethernet Switch
6- 6-13 Add Added new section 6.2.21 Remaining Connection Status
7- 7-1 Add Added Security command to the Commands main menu
7- 7-3 Add Added Reboot Relay command and description to the Relay Maintenance menu items
7- 7- Add Added Security menu and submenu commands and descriptions to the Command menu
Table H–5: MAJOR UPDATES FOR M60 MANUAL REVISION Y2 (Sheet 2 of 2)