EasyManua.ls Logo

GE MI-869 - Page 18

GE MI-869
552 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1–8 869 MOTOR PROTECTION SYSTEM – INSTRUCTION MANUAL
869 ORDER CODES CHAPTER 1: INTRODUCTION
Figure 1-3: 869 Order Codes
892800B8.PDF
869 E ** ** ** H * * A * N G * * * * * * * * * N
Interface 869 | | | |||||||||||||||||| 869 Motor Protection System
Language E | | | | | | | | | | | | | | | | | | | | English
Phase Currents ³
Slot J Bank 1/2
P1| |||||||||||||||||| 1A 3-phase current inputs (J1)
P5| |||||||||||||||||| 5A 3-phase current inputs (J1)
Phase Currents ³
Slot K Bank 1
NN | | | | | | | | | | | | | | | | | | No phase current inputs
P1 | | | | | | | | | | | | | | | | | | 1A 3-phase current inputs (K1)
P5 | | | | | | | | | | | | | | | | | | 5A 3-phase current inputs (K1)
Ground Currents G1 ||||||||||||||||| 1A ground input (J1)
G5||||||||||||||||| 5A ground input (J1)
B1|||||||||||||||||
1A ground (J1) + 50:0.025A
(K1, included with current protection M option only)
B5|||||||||||||||||
5A ground (J1) + 50:0.025A
(K1, included with current protection M option only)
0B||||||||||||||||| 50:0.025A (J1), only available if NN is selected for Slot K Bank 1
Power Supply L | | | | | | | | | | | | | | | | 24 to 48 V DC
H | | | | | | | | | | | | | | | | 110 to 250 V DC/110 to 230 V AC
Slot B - LV
IO
N||||||||||||||| None
R||||||||||||||| 6 X RTDS (PT100, NI100, NI120)
S||||||||||||||| 6 X RTDS (PT100, NI100, NI120, CU10)
Slot C- LV IO
N | | | | | | | | | | | | | | None
R | | | | | | | | | | | | | | 6 X RTDS (PT100, NI100, NI120)
S | | | | | | | | | | | | | | 6 X RTDS (PT100, NI100, NI120, CU10)
Slot F - HV IO A
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 Form A (Vmon), 3 Form C, 7 Digital Inputs (Low/High Voltage, Int/Ext
Supply)
Slot G - HV
IO
N | | | | | | | | | | | | None
A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 Form A (Vmon), 3 Form C, 7 Digital Inputs (Low/High Voltage, Int/Ext
Supply)
L | | | | | | | | | | | | 7 DcmA O/P + 4 DcmA I/P + 1 RTD (PT 100, NI 100, NI 120)
Slot H - HV
IO
N||||||||||| None (High Voltage I/O)
F||||||||||| 10 Digital Inputs + 4 Arc Flash Inputs
A
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 Form A (Vmon), 3 Form C, 7 Digital Inputs (Low/High Voltage, Int/Ext
Supply)
Faceplate M | | | | | | | | | | Basic = Membrane Keypad
G | | | | | | | | | | Standard = Rugged Keypad
Current Protection S | | | ||||||
Basic configuration: 14, 19, 37, 38, 46, 49, 50P, 50N, 50G, 50_2, 50LR,
51P, 51N, 51G, 66, 86
M
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Standard configuration: Basic configuration +67P, 67N, 87 (2nd CT Bank
required for 87)
Voltage Monitoring and Protection S
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Standard Voltage Monitoring & Protection: 24, 27P, 40, 40Q, 47, 59P, 59N,
59X, 81O, 81U, VTFF
P
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Advanced Voltage Monitoring & Protection: Standard Voltage
Monitoring & Protection +32, 55, 59_2, 78, 81R
Control B | ||||||
Basic control: Setpoint Group Control, Breaker/Contactor Control, Virtual
Inputs, Trip Bus
F||||||| Standard control: Basic control + FlexLogic, 50BF
Monitoring B
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Basic monitoring: Motor Health Report, Motor Start Report, Motor
Learned Data, Data Logger, Breakers Coil Monitoring, Breaker Arcing,
Harmonics, THD, Demand
C
|
|
|
|
|
|
|
|
|
|
|
|
Standard monitoring: Basic monitoring + Breaker Health Report, Broken
Rotor Bar
A | | | | | | Advanced: Standard + Harmonic Detection, Stator Inter-Turn Fault
Communications S E
|
|
|
|
|
|
|
|
Standard = USB, 1xRS485: Modbus RTU, DNP3.0, IEC60870-5-103 +
1xEthernet Copper: Modbus TCP, DNP3.0
1E
|
|
|
|
|
|
|
|
Advanced = USB, 1xRS485: Modbus RTU, DNP3.0, IEC60870-5-103 +
2xEthernet, Modbus TCP/IP, DNP3.0, IEC 60870-5-104, SNTP, 1588
1P|||| Advanced communications + PRP
2A|||| Advanced communications + IEC 61850
2E|||| Advanced communications + PRP + IEC 61850
Advanced Communications Connector N | | | None
S | | | ST, Multi-mode 1310 nm
C | | | RJ45, Copper 10/100M
Wireless Communication N | | None
W| | WiFi 802.11
Security B | Basic security
A | Advanced security: CyberSentry Level 1
Future Option N Not Available

Table of Contents

Related product manuals