OPTO 1
OPTO 2
OPTO 3
V CHECK
OPTO 5
OPTO 7
OPTO 6
OPTO 8
COMMON
CONNECTION
2. C.T. CONNECTIONS ARE SHOWN 1A CONNECTED AND ARE TYPICAL ONLY.
CHANGES IF THIS OPTION IS SELECTED IN THE RELAY MENU.
4. OPTO INPUTS 1 AND 2 MUST BE USED FOR SETTING GROUP
ENSURE CORRECT OPERATION OF THE PROTECTIVE RELAY.
OPTO 4
D8
+
1A
5A
C.T. SHORTING LINKS
PIN TERMINAL (P.C.B. TYPE)
(a)
(b)
NOTES 1.
3. THIS RELAY SHOULD BE ASSIGNED TO ANY TRIP TO
5. FOR COMMS OPTIONS SEE DRAWING 10Px4001.
C21
C22
N
C
C15
C19
C20
B
A
D15
-
D16
D18
D17
+
D12
D14
D13
+
+
-
D10
D11
D9
+
-
-
NOTE 2.
DIRECTION OF FORWARD CURRENT FLOW
C
B
A
a
n
c
b
N
P2P1P2
S1S2
S2 S1
1A
5A
1A
5A
1A
5A
1A
5A
C10
C12
C13
SENSITIVE
N
N
C9
C7
C
C6
C4
B
C3
D1
+
D7
D6
D5
+
-
-
D4
D3
D2
-
+
-
SYNC
C24
C23
MiCOM P145 (PART)
P1
C1
A
n
NOTE 4.
a c
b
PHASE ROTATION
A
C B
B
A
N
X
X
X
B
C
C
A
NOTE 5.
POWER SUPPLY VERSION 24-48V (NOMINAL) D.C. ONLY
SEE DRAWING
*
AC OR DC
x
AUX SUPPLY
+
-
J2
J1
*
+
EIA485/
PORT
KBUS
-
J16
SCN
J18
10Px4001.
J17
RELAY 24
RELAY 22
RELAY 23
RELAY 21
B14
B17
B18
B16
B15
B12
B13
B11
B10
RELAY 16
RELAY 14
RELAY 15
RELAY 13
RELAY 20
RELAY 19
RELAY 18
RELAY 17
G18
B7
B9
B8
B6
B5
B2
B4
B3
B1
G13
G16
G17
G14
G15
G11
G12
G9
G10
MiCOM P145 (PART)
F15
COMMS
COMMON
CONNECTION
OPTO 16
F17
F18
F16
OPTO 15
OPTO 14
OPTO 13
F11
F13
F14
F12
F9
F10
RELAY 4
RELAY 12
RELAY 10
RELAY 11
H17
RELAY 8
G6
G8
G7
G5
G4
G1
G3
G2
H18
RELAY 9
H12
H15
H16
H13
H14
RELAY 7
H10
H11
H8
H9
RELAY 5
RELAY 6
WATCHDOG
RELAY 3 ANY TRIP
CONTACT
WATCHDOG
CONTACT
J12
H5
H7
H6
H3
H4
RELAY 2
J14
H1
H2
J13
RELAY 1
J11
NOTE 3.
+
-
+
-
+
-
+
-
OPTO 12
F8
OPTO 10
OPTO 11
OPTO 9
F5
F6
F7
F4
F3
F2
F1
E13
E16
E18
E17
E15
E14
OPTO 24
OPTO 23
E3
E5
E4
E9
E11
E12
E10
E7
E8
E6
OPTO 22
OPTO 21
OPTO 18
OPTO 20
OPTO 19
E2
E1
OPTO 17
CONNECTION
COMMON
EARTH
CASE
Drg
No:
Issue: Revision:
Date:
Date:
Name:
Chkd:
DO NOT SCALE
CAD DATA 1:1 DIMENSIONS: mm
Title:
Substation Automation Solutions
ALSTOM GRID UK LTD
(STAFFORD)
Sht:
Next
Sht:
13/05/2013 H.ONG
FIELD VOLTAGE OUTPUT REMOVED. CID HONG-95RDV7
10P14505
1
-
EXT CONN DIAG: FEEDER PROT. RELAY (60TE) DIRECT'L PHASE
O/C & S.E.F. AUTORECLOSE & CHECK SYNCH. (24 I/P & 24 O/P)
D

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE MiCOM P145 Agile and is the answer not in the manual?

GE MiCOM P145 Agile Specifications

General IconGeneral
BrandGE
ModelMiCOM P145 Agile
CategoryControl Unit
LanguageEnglish

Related product manuals