18–14 MULTILINK ML2400 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL
MODBUS PROTOCOL CHAPTER 18: MODBUS PROTOCOL
0278 Port 9: Number of oversized frames
received
0 to
4294967295
1F9 0
027A Port 9: Number of bad fragments
received (<64 bytes)
0 to
4294967295
1F9 0
027C Port 9: Number of jabber frames
received
0 to
4294967295
1F9 0
027E Port 9: Number of collisions occurred 0 to
4294967295
1F9 0
0280 Port 9: Number of late collisions
occurred
0 to
4294967295
1F9 0
0282 Port 9: Number of 64-byte frames
received/sent
0 to
4294967295
1F9 0
0284 Port 9: Number of 65 to 127 byte
frames received/sent
0 to
4294967295
1F9 0
0286 Port 9: Number of 128 to 255 byte
frames received/sent
0 to
4294967295
1F9 0
0288 Port 9: Number of 256 to 511 byte
frames received/sent
0 to
4294967295
1F9 0
028A Port 9: Number of 512 to 1023 byte
frames received/sent
0 to
4294967295
1F9 0
028C Port 9: Number of 1023 to maximum
byte frames received/sent
0 to
4294967295
1F9 0
028E Port 9: Number of MAC error packets 0 to
4294967295
1F9 0
0290 Port 9: Number of dropped received
packets
0 to
4294967295
1F9 0
0292 Port 9: Number of multicast frames
sent
0 to
4294967295
1F9 0
0294 Port 9: Number of broadcast frames
sent
0 to
4294967295
1F9 0
0296 Port 9: Number of <64 byte fragments
with good CRC
0 to
4294967295
1F9 0
0298 Port 10: Number of bytes received 0 to
4294967295
1F9 0
029A Port 10: Number of bytes sent 0 to
4294967295
1F9 0
029C Port 10: Number of frames received 0 to
4294967295
1F9 0
029E Port 10: Number of frames sent 0 to
4294967295
1F9 0
02A0 Port 10: Total bytes received 0 to
4294967295
1F9 0
02A2 Port 10: Total frames received 0 to
4294967295
1F9 0
02A4 Port 10: Number of broadcast frames
received
0 to
4294967295
1F9 0
02A6 Port 10: Number of multicast frames
received
0 to
4294967295
1F9 0
02A8 Port 10: Number of frames with CRC
error
0 to
4294967295
1F9 0
02AA Port 10: Number of oversized frames
received
0 to
4294967295
1F9 0
02AC Port 10: Number of bad fragments
received (<64 bytes)
0 to
4294967295
1F9 0
02AE Port 10: Number of jabber frames
received
0 to
4294967295
1F9 0
Table 18–1: Modbus memory map (Sheet 12 of 33)
Address Description Range Step Format Default

Table of Contents

Other manuals for GE MultiLink ML1600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE MultiLink ML1600 and is the answer not in the manual?

GE MultiLink ML1600 Specifications

General IconGeneral
BrandGE
ModelMultiLink ML1600
CategorySwitch
LanguageEnglish

Related product manuals