02B0 Port 10: Number of collisions occurred 0 to
4294967295
1F9 0
02B2 Port 10: Number of late collisions
occurred
0 to
4294967295
1F9 0
02B4 Port 10: Number of 64-byte frames
received/sent
0 to
4294967295
1F9 0
02B6 Port 10: Number of 65 to 127 byte
frames received/sent
0 to
4294967295
1F9 0
02B8 Port 10: Number of 128 to 255 byte
frames received/sent
0 to
4294967295
1F9 0
02BA Port 10: Number of 256 to 511 byte
frames received/sent
0 to
4294967295
1F9 0
02BC Port 10: Number of 512 to 1023 byte
frames received/sent
0 to
4294967295
1F9 0
02BE Port 10: Number of 1023 to maximum
byte frames received/sent
0 to
4294967295
1F9 0
02C0 Port 10: Number of MAC error packets 0 to
4294967295
1F9 0
02C2 Port 10: Number of dropped received
packets
0 to
4294967295
1F9 0
02C4 Port 10: Number of multicast frames
sent
0 to
4294967295
1F9 0
02C6 Port 10: Number of broadcast frames
sent
0 to
4294967295
1F9 0
02C8 Port 10: Number of <64 byte fragments
with good CRC
0 to
4294967295
1F9 0
02CA Port 11: Number of bytes received 0 to
4294967295
1F9 0
02CC Port 11: Number of bytes sent 0 to
4294967295
1F9 0
02CE Port 11: Number of frames received 0 to
4294967295
1F9 0
02D0 Port 11: Number of frames sent 0 to
4294967295
1F9 0
02D2 Port 11: Total bytes received 0 to
4294967295
1F9 0
02D4 Port 11: Total frames received 0 to
4294967295
1F9 0
02D6 Port 11: Number of broadcast frames
received
0 to
4294967295
1F9 0
02D8 Port 11: Number of multicast frames
received
0 to
4294967295
1F9 0
02DA Port 11: Number of frames with CRC
error
0 to
4294967295
1F9 0
02DC Port 11: Number of oversized frames
received
0 to
4294967295
1F9 0
02DE Port 11: Number of bad fragments
received (<64 bytes)
0 to
4294967295
1F9 0
02E0 Port 11: Number of jabber frames
received
0 to
4294967295
1F9 0
02E2 Port 11: Number of collisions occurred 0 to
4294967295
1F9 0
02E4 Port 11: Number of late collisions
occurred
0 to
4294967295
1F9 0
02E6 Port 11: Number of 64-byte frames
received/sent
0 to
4294967295
1F9 0
Table 18–1: Modbus memory map (Sheet 13 of 33)
Address Description Range Step Format Default

Table of Contents

Other manuals for GE MultiLink ML1600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE MultiLink ML1600 and is the answer not in the manual?

GE MultiLink ML1600 Specifications

General IconGeneral
BrandGE
ModelMultiLink ML1600
CategorySwitch
LanguageEnglish

Related product manuals