GE Multilin N60 Network Stability and Synchrophasor Measurement System H-3
APPENDIX H H.1 CHANGE NOTES
H
All All Delete Deleted CPU options U and V
1-1 1-1 Update Updated Figure 1-1 Rear Nameplate
3-4 3-4 Update Updated Figure 3-6 Rear Terminal View
Table H–6: MAJOR UPDATES FOR N60 MANUAL REVISION Y1 (Sheet 1 of 2)
PAGE
(X2)
PAGE
(Y1)
CHANGE DESCRIPTION
All All Delete Deleted content pertaining to Ethernet switch
Title Title Update Changed part numbers. Updated address and contact information.
1-1 1-1 Update Updated address and contact information
2-3 2-3 Add Added CPU options T, U, and V, Software options Ax, Bx, Dx (for x=0,3,6,7,E,F,G,H), and display
options R and S to the order code tables
2-3 2-3 Delete Removed E,G,H,J,S from CPU options from order code tables
2-4 2-4 Add Added Russian modules R and S to order code Table 2-4
2-5 2-5 Delete Deleted 9S, 2S, 2T from replacement module order code Table 2-5
2-13 2-13 Update Updated Ethernet fiber table in section 2.2.8 Communications
3-6 3-6 Update Updated Figure 3-8 Typical Wiring Diagram
3-19 3-19 Update Deleted references to COM 1 RS485 port in section 3.2.9 CPU Communication Ports. Revised
text and Figure 3-20 CPU Module Communications Wiring to include only modules T, U, V in
section 3.2.9a.
5-1 5-1 Update Updated the front panel main menu to include the CyberSentry security menu
5-15 5-15 Update Update Communications main menu to remove the SNTP Protocol submenu
5-16 5-16 Delete Deleted references to COM 1 RS485 port in section 5.2.4b Serial Ports
5-16 5-16 Add Added section 5.2.4c Ethernet Network Topology
5-16 5-16 Update Updated Networks section 5.2.4d to include all three Ethernet ports
5-17 5-17 Update Added 0 as valid number to section 5.2.4e Modbus Protocol section
5-37 5-36 Delete Deleted Local Time Offset, Daylight Savings Time, DST (start/stop for month/day/hour) from Real
Time Clock menu
5-37 5-36 Add Added submenus Precision Time Protocol, SNTP Protocol, and Local Time and Synchronizing
Source settings to Real Time Clock menu
5-37 5-37 Add Added new Precision Time Protocol (1588) menu and setting descriptions
5-36 5-39 Update Changed Communication to Real Time Clock in SNTP protocol settings path. Moved SNTP
Protocol menu and settings descriptions to Real Time Clock subsection
5-36 5-35 Delete Deleted section k) SNTP Protocol and the settings descriptions
5- 5-40 Add Added new section for Local Time menu settings and settings description
5-47 5-49 Add Added new PTP Fail menu item to the User-Programmable Self Tests menu
5-82 5-85 Update Changed precise IRIG-B input note to include PTP and international time standard information.
5- 5- Add Added PTP Failure and CLOCK UNSYNCHRONIZED to Flexlogic Operands table
5- 5- Add Added to Minor self-test error message **Bad PTP Signal**
5-81 5-83 Update Updated PMU main menu to add aggregator and control block menu items
5-81 5-83 Add Added UR Synchrophasor Implementation of IEC61850-90-5 to the PMU software option
description
5-81 5-84 Update Updated Figure 5-24 Complete Synchrophasor Implementation
5-81 5-84 Add Added Figure 5-25 N60 Support For Four Logical Device PMU
5-81 5-84 Update Updated Table 5-6 Implementation By Model Number
5-82 5-85 Add Added Figure 5-26 Logical Nodes Supported In Each Logical Device
5-82 5-86 Add Added Figure 5-27 Protection Synchrophasors Example Data Set
5-82 5-87 Add Added Figure 5-28 Data Set Created From User Selected Internal Items
Table H–5: MAJOR UPDATES FOR N60 MANUAL REVISION Y2 (Sheet 2 of 2)
PAGE
(Y1)
PAGE
(Y2)
CHANGE DESCRIPTION