NX-8E CONTROL
18
L LOCATION 21 - DOWNLOAD CONTROL (1 segment, feature selection data)
Location 21 contains the feature selections for the controlling of download sessions. The following features can be
enabled or disabled using this location. (See the feature definitions beginning on page 3)
Segment 1:
1 - On enables two call answering machine defeat.
2 - On enables tone sniff answering machine defeat.
3 - On requires call back before download session.
4 - Shutdown (can only be viewed from the keypad, must be changed through downloading).
5 - On locks all local programming. (can only be viewed from the keypad, must be changed through
downloading)
6 - On locks programming of all locations associated with the communicator (can only be viewed from the
keypad, must be changed through downloading)
7 - On locks out download section. (can only be viewed from the keypad, must be changed through
downloading. If "On", locations 19 - 22 cannot be viewed from the keypad; can only be viewed
from the keypad when "Off".)
8 - On enables call back at auto test interval.
L LOCATION 22 - DOWNLOAD CALL BACK NUMBER (20 segments, numerical data)
If a telephone number is programmed into this location, and "Require Callback" is enabled in location 21, the control
panel will hang up for approximately 36 seconds (ensuring that the calling party has disconnected), and then call
back. If tone dialing is desired, program an "15" in the segment where tone dialing should begin. If the entire number
should be tone dialing, program an A15" in the first segment. Four-second delays can be obtained anywhere in the
sequence by programming a "13" in the appropriate delay location. WARNING: THE CALLBACK PHONE NUMBER
SHOULD ALWAYS BE REVIEWED FOR ACCURACY BEFORE DISCONNECTING.
L LOCATION 23 - PARTITION 1, FEATURE AND REPORT SELECTIONS (5 segments, feature selection data)
Location 23 is used to enable certain features that can be accessed or are visible to the user from the keypad of the
system. In addition, certain communicator reports are enabled in location 23. Each of these features can be enabled
by partition. For additional partition information see locations 88-109 on pages 30-32. If the feature selection
location for any partition is left blank, that partition will use this location for the feature selection.
This location contains 3 segments of 8 features each. (See the feature definitions beginning on page 3.)
Segment 1: 1 - On enables the Quick Arm feature.
2 - On enables the Re-exit feature.
3 - On enables the Automatic Bypass feature.
4 - On enables the Silent Keypad Panic feature (overrides the audible panic selection).
5 - On enables the Audible Keypad Panic feature.
6 - On enables the Keypad Aux 1 feature (FIRE).
7 - On enables the Keypad Aux 2 feature (MEDICAL).
8 - On enables the Keypad Multiple Code Attempt Tamper feature.
Segment 2: 1 - On enables the LED Extinguish feature.
2 - On enables the Require Code for Bypassing feature.
3 - On enables the Zone Bypassed Sounder Alert feature.
4 - On enables the AC Power/Low Battery Sounder Alert feature.
5 - On enables Bypass toggle.
6 - On enables Silent Auto Arm.
7 - On enables the Automatic Instant feature.
8 – On enables Instant mode. (Applies to NX1208E / NX1248E)
Segment 3: 1 - On enables Opening and Closing reports.
2 - On enables Zone Bypass reporting.
3 - On enables Zone Restore reporting.
4 - On enables Zone Trouble reporting.
5 - On enables Zone Tamper reporting.
6 - On enables the Cancel reporting.
7 - On enables the Recent Closing report.
8 - On enables the Exit Error report.

Other manuals for GE NetworX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX Series and is the answer not in the manual?

GE NetworX Series Specifications

General IconGeneral
ModelNetworX Series
ZonesVaries by model (e.g., 8, 16, 32, 64)
PartitionsVaries by model (typically 1-8)
KeypadsSupports multiple keypads
CommunicationPhone line, cellular, IP
Power Supply16.5 VAC
Backup Battery12VDC, 7AH
User CodesVaries by model (e.g., 48, 150, 300)
Event BufferVaries by model (e.g., 200, 500, 1000 events)
Operating Temperature0°C to 49°C (32°F to 120°F)
Communication ProtocolContact ID, SIA
WeightVaries by model
DimensionsVaries by model (e.g., 14.5" x 12.5" x 3.5")