NX-8E CONTROL
23
Segment 6: 1 = Enable 2 wire smoke.
2 = Reserved.
3 = Enable for Zone Activity in Hours (not Days)
4 = Enable Daylight Savings Time (DST)
5 = Reserved
6 = On to disable Clean Me report (Clean Me report is enabled at default)
7-8 = Reserved.
Segment 7: Reserved
L LOCATION 38 - SWINGER SHUTDOWN COUNT
Location 38 contains the number of trips during an arming cycle that the NX8 will allow before bypassing a zone.
The count determination is described in the feature definitions beginning on page 3. NOTE: For UL
installations, this feature shall be disabled.
.
L LOCATION 39 - KEYPAD SOUNDER CONTROL (1 segment, feature selection data)
Segment 1: 1 - On if keypad sounds for ATelephone Line Cut@ when the system is armed.
2 - On if keypad sounds for ATelephone Line Cut@ when disarmed.
3 - On if keypad sounds upon AC Power Failure.
4 - On if keypad sounds when a Low Battery is detected.
5 - On if keypad sounds during Cross Zone trip time.
6 - On if keypad sounds for zone and box tampers.
7 - Reserved.
8 - On if keypad sounds for expander trouble (required for UL installations).
L LOCATION 40 - SYSTEM TIMERS (14 segments, numerical data)
Location 40 contains the duration of various system timing functions. Example: If you desire the duration of the
Dynamic Battery Test to be 30 minutes, you should program [3]-[0]-[r] in segment 1 of this location. The [3]-[0]
is the number of minutes, and the [r] stores the data and moves to the next segment of this location.
Segment 1 - Dynamic Battery Test duration in minutes 0-255 minutes ("0" = no test)
Segment 2 - AC Fail report delay in minutes 0-255 minutes.
Segment 3 - Power Up Delay in seconds 0-60 seconds ("0" = no power up delay).
Segment 4 - Siren Time in minutes 1-255 minutes.
Segment 5 - Telephone Line Cut delay in seconds 0-255 seconds ("0" = no TLM).
Segment 6 - Cross Zone time in minutes 0-255 ("0" = no cross zoning).
Segment 7 - Chime time in 50 mS (1/20th second) increments from 0-12 seconds ("0" = follows zone 255
latched).
Segment 8 - Dial delay in seconds 0-255 seconds (“0 ” = no abort delay).
Segment 9 - Fire Alarm Verification time in seconds 120-255 seconds ("0" = no fire alarm verification).
NOTE: This feature is not approved for residential use in California
Segment 10 -Listen-In time in seconds 0-255 ("0" = no Listen-In time).
Segment 11 –Zone Activity Monitor feature timed in days 0 – 255 (“0” = disabled)
Segments 12-14 Reserved.
Note: The "Listen-In" feature cannot be enabled for UL Listed systems. The "Dynamic Battery
Test" feature cannot exceed four (4) hours. The dial delay shall be set to -0-.
LOCATION 41 - SPECIAL FEATURES (1 segment, feature selection data)
Segment 1:
1 - On enables the 6-digit code option. If 6-digit option is enabled, all arm/disarm codes and the "Go To
Program Code" are 6 digits. If this option is enabled, the default user 1 code is [1]-[2]-[3]-[4]-[5]-[6].
NOTE: IF YOU ENABLE THIS OPTION, VERIFY THAT THE "GO TO PROGRAM CODE" IS A SIX-
DIGIT CODE BEFORE EXITING PROGRAMMING.
2 - On requires code entry for [r]-[9]-[8] (perform call back download) and [r]-[9]-[9] (answer incoming
call for download) functions.
3 - Enable Auto Cancel / Abort (Refer to feature definitions beginning on page 3)
4 - Enable Walk-Test Mode (Refer to feature definitions beginning on page 3)
5-8 Reserved.

Other manuals for GE NetworX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX Series and is the answer not in the manual?

GE NetworX Series Specifications

General IconGeneral
ModelNetworX Series
ZonesVaries by model (e.g., 8, 16, 32, 64)
PartitionsVaries by model (typically 1-8)
KeypadsSupports multiple keypads
CommunicationPhone line, cellular, IP
Power Supply16.5 VAC
Backup Battery12VDC, 7AH
User CodesVaries by model (e.g., 48, 150, 300)
Event BufferVaries by model (e.g., 200, 500, 1000 events)
Operating Temperature0°C to 49°C (32°F to 120°F)
Communication ProtocolContact ID, SIA
WeightVaries by model
DimensionsVaries by model (e.g., 14.5" x 12.5" x 3.5")