NX-8E CONTROL
26
L LOCATION 51 - AUTOTEST CONTROL (4 segments, numerical data)
Segment 1: Program a "1" if the interval is to be in hours; Program a "0" if in days. Add a A2" to suppress
the daily test or a A3" to suppress the hourly test if any report has been sent.
Segment 2: Program the Autotest interval from 1-255 hours/days.
Segment 3: Program the Autotest report hour in 24-hour format (if the interval is in hours, this segment is
ignored).
Segment 4: Program the Autotest report time, number of minutes after the hour.
LOCATION 52 - OPENING TIME (2 segments, numerical data)
Location 52 contains the time in 24 hour format the NX-8E enables codes designated as arm only after closing.
This time is only valid on those days programmed in location 54. Note: Opening time must be earlier than
closing time for Auto Arm, Aux. Outputs, or Code Authorization to function properly.
Segment 1: Program the hour of the opening time.
Segment 2: Program the minutes after the hour of the opening time.
LOCATION 53 - CLOSING TIME/AUTOMATIC ARMING TIME (2 segments, numerical data)
Location 53 contains the time in 24 hour format the NX-8E disables the disarm capability for codes designated as
arm only after closing. This is also the time the Automatic Arming sequence will begin (if enabled in location 55)..
Segment 1: Program the hour of the closing / auto arm time.
Segment 2: Program the minutes after the hour of the closing / auto arm time.
LOCATION 54 - DAYS OF THE WEEK EACH PARTITION IS OPEN (8 Segments, feature selection data)
Location 54 selects which days of the week each partition is open. On these days, Aarm only after close window@
codes will be able to arm and disarm during open window. NOTE: If any partition is not programmed to be
opened and is programmed to Auto-Arm (Location 55), the NX-8E will try to arm every 45 minutes for the
duration of the closed period unless Auto Retry is disabled in location 55. On days not selected here, Aarm
only after close window@ codes will not disarm. Segment 1 is for partition 1, and segment 8 is for partition 8. (See
locations 52 and 53 for the opening and closing times for the open days.)
Segment 1-8: 1 - Open on Sunday.
2 - Open on Monday.
3 - Open on Tuesday.
4 - Open on Wednesday.
5 - Open on Thursday.
6 - Open on Friday.
7 - Open on Saturday.
8 – Reserved.
LOCATION 55 - DAYS OF THE WEEK FOR AUTO ARMING IN PARTITIONS 1 THRU 8 (8 Segments, feature
selection data)
Location 55 selects which days each partition will auto arm. Segment 1 is for partition 1, and segment 8 is for
partition 8. If a zone is faulted when the panel tries to auto arm, the zone will be bypassed.
Segments 1-8: 1 - Auto Arming on Sunday.
2 - Auto Arming on Monday.
3 - Auto Arming on Tuesday.
4 - Auto Arming on Wednesday.
5 - Auto Arming on Thursday.
6 - Auto Arming on Friday.
7 - Auto Arming on Saturday.
8 - Disable 45 minute retry timer.

Other manuals for GE NetworX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX Series and is the answer not in the manual?

GE NetworX Series Specifications

General IconGeneral
ModelNetworX Series
ZonesVaries by model (e.g., 8, 16, 32, 64)
PartitionsVaries by model (typically 1-8)
KeypadsSupports multiple keypads
CommunicationPhone line, cellular, IP
Power Supply16.5 VAC
Backup Battery12VDC, 7AH
User CodesVaries by model (e.g., 48, 150, 300)
Event BufferVaries by model (e.g., 200, 500, 1000 events)
Operating Temperature0°C to 49°C (32°F to 120°F)
Communication ProtocolContact ID, SIA
WeightVaries by model
DimensionsVaries by model (e.g., 14.5" x 12.5" x 3.5")