SLOW COMMUNICATOR FORMAT CODES
NX-8E CONTROL
29
LOCATION 74 - EXPANDER TROUBLE / EXPANDER TROUBLE RESTORE COMMUNICATOR CODES (4
segments, numerical data)
Location 74 contains the digits for a 4+2 format that will be sent if "Expander Trouble Reporting" is enabled.
Segments 1 & 2 contain the digits of the "Expander Trouble Reporting". Segments 3 & 4 contain the digits of the
"Expander Trouble Restore". Refer to the box on page 27.
LOCATION 75 - FAIL TO COMMUNICATE COMMUNICATOR CODE (2 segments, numerical data)
Location 75 contains the digits for a 4+2 format that will be sent if the "Fail To Communicate Reporting" is enabled.
Refer to the box on page 27.
LOCATION 76 - LOG FULL COMMUNICATOR CODE (2 segments, numerical data)
Location 76 contains the digits for a 4+2 format if the "Log Full Reporting" is enabled. Refer to the box on page 27.
LOCATION 77 - OPENING COMMUNICATOR CODE (8 segments, numerical data)
Location 77 contains the digit of a 4+2 format if the "Opening Reporting" is enabled. Refer to the box on page 27.
Segment 1 = Partition 1 Segment 3 = Partition 3 Segment 5 = Partition 5 Segment 7 = Partition 7
Segment 2 = Partition 2 Segment 4 = Partition 4 Segment 6 = Partition 6 Segment 8 = Partition 8
LOCATION 78 - CLOSING COMMUNICATOR CODE (8 segments, numerical data)
Location 78 contains the digit of a 4+2 format if the "Closing Reporting" is enabled. Refer to the box on page 27.
Segment 1 = Partition 1 Segment 3 = Partition 3 Segment 5 = Partition 5 Segment 7 = Partition 7
Segment 2 = Partition 2 Segment 4 = Partition 4 Segment 6 = Partition 6 Segment 8 = Partition 8
LOCATION 79 - AUTOTEST COMMUNICATOR CODE (2 segments, numerical data)
Location 79 contains the digits for a 4+2 format that will be sent if the "Autotest" or "Manual Test" is enabled. Refer to
the box on page 27.
LOCATION 80 - RECENT CLOSING AND EXIT ERROR COMMUNICATOR CODE (2 segments, numerical data)
Location 80 contains the digits for a 4+2 format that will be sent if "Recent Closing" and/or "Exit Error Reporting" is
enabled. Segment 1 contains the digit for the "Recent Closing Reporting". Segment 2 contains the digit for the "Exit
Error Reporting". Refer to the box on page 27.
LOCATION 81 - START PROGRAM AND END PROGRAM COMMUNICATOR CODES (4 segments, numerical
data)
Location 81 contains the digits for a 4+2 format that will be sent if "Start / End Programming Reporting" is enabled.
Segment 1 contains the digit for the "Start Program Reporting". Segment 2 contains the digit for the "Start Program
Reporting". Segment 3 contains the digit for the "End Program Reporting". Segment 4 contains the digit for the "End
Program Reporting". Refer to the box on page 27.
LOCATION 82 - END DOWNLOAD COMMUNICATOR CODE (4 segments, numerical data)
Location 82 contains the digits for a 4+2 format that will be sent if "End Downloading Reporting" is enabled. Segment
1 and 2 are Reserved. Segment 3 contains the digit of the "End Download Reporting". Segment 4 contains the digit
of the "End Download Reporting". Note: A start download report will be sent to the internal event log. Refer to the box
on page 27.
LOCATION 83 - CANCEL COMMUNICATOR CODE (1 segments, numerical data)
Location 83 contains the digit for a 4+2 format that will be sent if "Cancel Reporting" is enabled. Segment 1 contains
the digit for the "Cancel Communicator Reporting". Refer to the box on page 27.
LOCATIONS 84-87 RESERVED.

Other manuals for GE NetworX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX Series and is the answer not in the manual?

GE NetworX Series Specifications

General IconGeneral
ModelNetworX Series
ZonesVaries by model (e.g., 8, 16, 32, 64)
PartitionsVaries by model (typically 1-8)
KeypadsSupports multiple keypads
CommunicationPhone line, cellular, IP
Power Supply16.5 VAC
Backup Battery12VDC, 7AH
User CodesVaries by model (e.g., 48, 150, 300)
Event BufferVaries by model (e.g., 200, 500, 1000 events)
Operating Temperature0°C to 49°C (32°F to 120°F)
Communication ProtocolContact ID, SIA
WeightVaries by model
DimensionsVaries by model (e.g., 14.5" x 12.5" x 3.5")