NX-8E CONTROL
42
LOCATION 206 – AUTO DISARM DAY SELECTOR (8 segments of feature selection data)
Location 206 selects which days each partition will auto disarm. Segment 1 is for partition 1, and segment 8 is for
partition 8. If a zone is faulted when the panel tries to auto disarm, the zone will be bypassed.
Segments 1-8: 1 - Auto Disarming on Sunday.
2 - Auto Disarming on Monday.
3 - Auto Disarming on Tuesday.
4 - Auto Disarming on Wednesday.
5 - Auto Disarming on Thursday.
6 - Auto Disarming on Friday.
7 - Auto Disarming on Saturday.
8 - Reserved.
LOCATION 207 – SERIAL PORT SELECTOR (1 segment of feature selection data)
Location 206 enables the serial port operations. There is one segment
0” = Disabled (Default) 1” = NX584 enabled 2” = Serial Printer Enabled.
LOCATION 208 – BAUD RATE TABLE (1 segment of numerical data)
The NX584 can operate on a number of different baud rates. Consult the home automation application information to
determine the best baud rate for your application and program it in Location 208. The default is “2” – 9600 Baud or
the serial printer baud rate.
0 = 2400 Baud (2.4K) 2 = 9600 Baud (9.6K) 4 = 38400 Baud (38.4K)
1 = 4800 Baud (4.8K) 3 = 19200 Baud (19.2K) 5-7 = Reserved
LOCATION 209 – PROGRAMMING THE NX-8E HOME AUTOMATION PROTOCOL (1 segment of numerical data)
The NX-8E home automation protocol can operate in one of two possible modes - binary or ASCII. Consult the home
automation application information to determine the proper mode for your application and program it in Location 209.
The default is “Off” – Binary.
Option 1 LED 0ff = Binary LED On = ASCII
Options 2 - 8 Reserved
LOCATION 210 – ENABLING THE NX-8E TRANSITION-BASED BROADCASTS (2 segments of feature
selection data)
The NX-8E can be programmed to automatically send information to the home automation system whenever there has
been a change in this information. This is referred to as ‘transition-based broadcasting’. Which information packets
use ‘transition-based broadcasting’ is dependent upon the application and the capabilities of the home automation
system. Location 210 is used to enable and disable the appropriate transition based broadcasts. Consult the home
automation application information and enable the appropriate transition based broadcasts in Location 210.
Segment 1:
DATA ENABLES TRANSITION
1 Reserved
2 Interface Configuration at power-up / end of download / program mode
3-4 Reserved
5 Zone Status Message
6 Zones Snapshot Message
7 Partition Status Message
8 Partitions Snapshot Message
Segment 2:
DATA ENABLES TRANSITION
1 System Status Message
2 X-10 Message Received
3 Log Event Message
4 Keypad Message Received
5 - 8 Reserved

Other manuals for GE NetworX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX Series and is the answer not in the manual?

GE NetworX Series Specifications

General IconGeneral
ModelNetworX Series
ZonesVaries by model (e.g., 8, 16, 32, 64)
PartitionsVaries by model (typically 1-8)
KeypadsSupports multiple keypads
CommunicationPhone line, cellular, IP
Power Supply16.5 VAC
Backup Battery12VDC, 7AH
User CodesVaries by model (e.g., 48, 150, 300)
Event BufferVaries by model (e.g., 200, 500, 1000 events)
Operating Temperature0°C to 49°C (32°F to 120°F)
Communication ProtocolContact ID, SIA
WeightVaries by model
DimensionsVaries by model (e.g., 14.5" x 12.5" x 3.5")