NX-8E CONTROL
41
L LOCATION 198 - ZONES 161-168 ZONE TYPE (8 segments, numerical data)
Location 198 contains the Zone Type for zones 161-168. Segment 1 is for zone 161; Segment 8 is for zone 168.
Default Zone Types are found in the table on page 19. To customize a Zone Type, see page 33.
LOCATION 199 - PARTITION SELECT, ZONES 161-168 (8 segments of feature selection data)
Location 199 is used to select the partition(s) that zones 161-168 reside in. A zone may reside in any combination of
the 8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are
armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1
corresponds to zone 161 and Segment 8 corresponds to zone 168.
Segments 1 - 8:
1 = Partition #1 3 = Partition #3 5 = Partition #5 7 = Partition #7
2 = Partition #2 4 = Partition #4 6 = Partition #6 8 = Partition #8
L LOCATION 200 - ZONES 169-176 ZONE TYPE (8 segments, numerical data)
Location 200 contains the Zone Type for zones 169-176. Segment 1 is for zone 169; Segment 8 is for zone 176.
Default Zone Types are found in the table on page 19. To customize a Zone Type, see page 33.
LOCATION 201 - PARTITION SELECT, ZONES 169-176 (8 segments of feature selection data)
Location 201 is used to select the partition(s) that zones 169-176 reside in. A zone may reside in any combination of
the 8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are
armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1
corresponds to zone 169 and Segment 8 corresponds to zone 176.
Segments 1 - 8:
1 = Partition #1 3 = Partition #3 5 = Partition #5 7 = Partition #7
2 = Partition #2 4 = Partition #4 6 = Partition #6 8 = Partition #8
L LOCATION 202 - ZONES 177-184 ZONE TYPE (8 segments, numerical data)
Location 202 contains the Zone Type for zones 177-184. Segment 1 is for zone 177; Segment 8 is for zone 184.
Default Zone Types are found in the table on page 19. To customize a Zone Type, see page 33.
LOCATION 203 - PARTITION SELECT, ZONES 177-184 (8 segments of feature selection data)
Location 203 is used to select the partition(s) that zones 177-184 reside in. A zone may reside in any combination of
the 8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are
armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1
corresponds to zone 177 and Segment 8 corresponds to zone 184.
Segments 1 - 8:
1 = Partition #1 3 = Partition #3 5 = Partition #5 7 = Partition #7
2 = Partition #2 4 = Partition #4 6 = Partition #6 8 = Partition #8
L LOCATION 204 - ZONES 185-192 ZONE TYPE (8 segments, numerical data)
Location 204 contains the Zone Type for zones 185-192. Segment 1 is for zone 185; Segment 8 is for zone 192.
Default Zone Types are found in the table on page 19. To customize a Zone Type, see page 33.
LOCATION 205 - PARTITION SELECT, ZONES 185-192 (8 segments of feature selection data)
Location 205 is used to select the partition(s) that zones 185-192 reside in. A zone may reside in any combination of
the 8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are
armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1
corresponds to zone 185 and Segment 8 corresponds to zone 192.
Segments 1 - 8:
1 = Partition #1 3 = Partition #3 5 = Partition #5 7 = Partition #7
2 = Partition #2 4 = Partition #4 6 = Partition #6 8 = Partition #8

Other manuals for GE NetworX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX Series and is the answer not in the manual?

GE NetworX Series Specifications

General IconGeneral
ModelNetworX Series
ZonesVaries by model (e.g., 8, 16, 32, 64)
PartitionsVaries by model (typically 1-8)
KeypadsSupports multiple keypads
CommunicationPhone line, cellular, IP
Power Supply16.5 VAC
Backup Battery12VDC, 7AH
User CodesVaries by model (e.g., 48, 150, 300)
Event BufferVaries by model (e.g., 200, 500, 1000 events)
Operating Temperature0°C to 49°C (32°F to 120°F)
Communication ProtocolContact ID, SIA
WeightVaries by model
DimensionsVaries by model (e.g., 14.5" x 12.5" x 3.5")