NX-8E CONTROL
40
Segments 1 - 8:
1 = Partition #1 3 = Partition #3 5 = Partition #5 7 = Partition #7
2 = Partition #2 4 = Partition #4 6 = Partition #6 8 = Partition #8
L LOCATION 190 - ZONES 129-136 ZONE TYPE (8 segments, numerical data)
Location 190 contains the Zone Type for zones 129-136. Segment 1 is for zone 129; Segment 8 is for zone 136.
Default Zone Types are found in the table on page 19. To customize a Zone Type, see page 33.
LOCATION 191 - PARTITION SELECT, ZONES 129-136 (8 segments of feature selection data)
Location 191 is used to select the partition(s) that zones 129-136 reside in. A zone may reside in any combination of
the 8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are
armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1
corresponds to zone 129 and Segment 8 corresponds to zone 136.
Segments 1 - 8:
1 = Partition #1 3 = Partition #3 5 = Partition #5 7 = Partition #7
2 = Partition #2 4 = Partition #4 6 = Partition #6 8 = Partition #8
L LOCATION 192 - ZONES 137-144 ZONE TYPE (8 segments, numerical data)
Location 192 contains the Zone Type for zones 137-144. Segment 1 is for zone 137; Segment 8 is for zone 144.
Default Zone Types are found in the table on page 19. To customize a Zone Type, see page 33.
LOCATION 193 - PARTITION SELECT, ZONES 137-144 (8 segments of feature selection data)
Location 193 is used to select the partition(s) that zones 137-144 reside in. A zone may reside in any combination of
the 8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are
armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1
corresponds to zone 137 and Segment 8 corresponds to zone 144.
Segments 1 - 8:
1 = Partition #1 3 = Partition #3 5 = Partition #5 7 = Partition #7
2 = Partition #2 4 = Partition #4 6 = Partition #6 8 = Partition #8
L LOCATION 194 - ZONES 145-152 ZONE TYPE (8 segments, numerical data)
Location 194 contains the Zone Type for zones 145-152. Segment 1 is for zone 145; Segment 8 is for zone 152.
Default Zone Types are found in the table on page 19. To customize a Zone Type, see page 33.
LOCATION 195 - PARTITION SELECT, ZONES 145-152 (8 segments of feature selection data)
Location 195 is used to select the partition(s) that zones 145-152 reside in. A zone may reside in any combination of
the 8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are
armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1
corresponds to zone 145 and Segment 8 corresponds to zone 152.
Segments 1 - 8:
1 = Partition #1 3 = Partition #3 5 = Partition #5 7 = Partition #7
2 = Partition #2 4 = Partition #4 6 = Partition #6 8 = Partition #8
L LOCATION 196 - ZONES 153-160 ZONE TYPE (8 segments, numerical data)
Location 196 contains the Zone Type for zones 153-160. Segment 1 is for zone 153; Segment 8 is for zone 160.
Default Zone Types are found in the table on page 19. To customize a Zone Type, see page 33.
LOCATION 197 - PARTITION SELECT, ZONES 153-160 (8 segments of feature selection data)
Location 197 is used to select the partition(s) that zones 153-160 reside in. A zone may reside in any combination of
the 8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are
armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1
corresponds to zone 153 and Segment 8 corresponds to zone 160.
Segments 1 - 8:
1 = Partition #1 3 = Partition #3 5 = Partition #5 7 = Partition #7
2 = Partition #2 4 = Partition #4 6 = Partition #6 8 = Partition #8

Other manuals for GE NetworX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX Series and is the answer not in the manual?

GE NetworX Series Specifications

General IconGeneral
ModelNetworX Series
ZonesVaries by model (e.g., 8, 16, 32, 64)
PartitionsVaries by model (typically 1-8)
KeypadsSupports multiple keypads
CommunicationPhone line, cellular, IP
Power Supply16.5 VAC
Backup Battery12VDC, 7AH
User CodesVaries by model (e.g., 48, 150, 300)
Event BufferVaries by model (e.g., 200, 500, 1000 events)
Operating Temperature0°C to 49°C (32°F to 120°F)
Communication ProtocolContact ID, SIA
WeightVaries by model
DimensionsVaries by model (e.g., 14.5" x 12.5" x 3.5")