LOCATION 181 - PARTITION SELECT, ZONES 89-96 (8 segments of feature selection data)
Location 181 is used to select the partition(s) that zones 89 - 96 reside in. A zone may reside in any combination of
the 8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are
armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1
corresponds to zone 89 and Segment 8 corresponds to zone 96.
Segments 1 - 8:
1 = Partition #1 3 = Partition #3 5 = Partition #5 7 = Partition #7
2 = Partition #2 4 = Partition #4 6 = Partition #6 8 = Partition #8
L LOCATION 182 - ZONES 97-104 ZONE TYPE (8 segments, numerical data)
Location 182 contains the Zone Type for zones 97-104. Segment 1 is for zone 97; Segment 8 is for zone 104.
Default Zone Types are found in the table on page 19. To customize a Zone Type, see page 33.
LOCATION 183 - PARTITION SELECT, ZONES 97-104 (8 segments of feature selection data)
Location 183 is used to select the partition(s) that zones 97-104 reside in. A zone may reside in any combination of
the 8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are
armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1
corresponds to zone 97 and Segment 8 corresponds to zone 104.
Segments 1 - 8:
1 = Partition #1 3 = Partition #3 5 = Partition #5 7 = Partition #7
2 = Partition #2 4 = Partition #4 6 = Partition #6 8 = Partition #8
L LOCATION 184 - ZONES 105-112 ZONE TYPE (8 segments, numerical data)
Location 184 contains the Zone Type for zones 105-112. Segment 1 is for zone 105; Segment 8 is for zone 112.
Default Zone Types are found in the table on page 19. To customize a Zone Type, see page 33.
LOCATION 185 - PARTITION SELECT, ZONES 105-112 (8 segments of feature selection data)
Location 185 is used to select the partition(s) that zones 105-112 reside in. A zone may reside in any combination of
the 8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are
armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1
corresponds to zone 105 and Segment 8 corresponds to zone 112.
Segments 1 - 8:
1 = Partition #1 3 = Partition #3 5 = Partition #5 7 = Partition #7
2 = Partition #2 4 = Partition #4 6 = Partition #6 8 = Partition #8
L LOCATION 186 - ZONES 113-120 ZONE TYPE (8 segments, numerical data)
Location 186 contains the Zone Type for zones 113-120. Segment 1 is for zone 113; Segment 8 is for zone 120.
Default Zone Types are found in the table on page 19. To customize a Zone Type, see page 33.
LOCATION 187 - PARTITION SELECT, ZONES 113-120 (8 segments of feature selection data)
Location 187 is used to select the partition(s) that zones 113-120 reside in. A zone may reside in any combination of
the 8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are
armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1
corresponds to zone 113 and Segment 8 corresponds to zone 120.
Segments 1 - 8:
1 = Partition #1 3 = Partition #3 5 = Partition #5 7 = Partition #7
2 = Partition #2 4 = Partition #4 6 = Partition #6 8 = Partition #8
L LOCATION 188 - ZONES 121-128 ZONE TYPE (8 segments, numerical data)
Location 188 contains the Zone Type for zones 121-128. Segment 1 is for zone 121; Segment 8 is for zone 128.
Default Zone Types are found in the table on page 19. To customize a Zone Type, see page 33.
LOCATION 189 - PARTITION SELECT, ZONES 121-128 (8 segments of feature selection data)
Location 189 is used to select the partition(s) that zones 121-128 reside in. A zone may reside in any combination of
the 8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are
armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1
corresponds to zone 121 and Segment 8 corresponds to zone 128.

Other manuals for GE NetworX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX Series and is the answer not in the manual?

GE NetworX Series Specifications

General IconGeneral
ModelNetworX Series
ZonesVaries by model (e.g., 8, 16, 32, 64)
PartitionsVaries by model (typically 1-8)
KeypadsSupports multiple keypads
CommunicationPhone line, cellular, IP
Power Supply16.5 VAC
Backup Battery12VDC, 7AH
User CodesVaries by model (e.g., 48, 150, 300)
Event BufferVaries by model (e.g., 200, 500, 1000 events)
Operating Temperature0°C to 49°C (32°F to 120°F)
Communication ProtocolContact ID, SIA
WeightVaries by model
DimensionsVaries by model (e.g., 14.5" x 12.5" x 3.5")