EasyManuals Logo

GE NetworX Series Installation And Start-Up Manual

GE NetworX Series
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #40 background imageLoading...
Page #40 background image
NX-8E CONTROL
38
LOCATION 173 - PARTITION SELECT, ZONES 57-64 (8 segments of feature selection data)
Location 173 is used to select the partition(s) that zones 57-64 reside in. A zone may reside in any combination of the
8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are
armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1
corresponds to zone 57 and Segment 8 corresponds to zone 64.
Segments 1 - 8:
1 = Partition #1 3 = Partition #3 5 = Partition #5 7 = Partition #7
2 = Partition #2 4 = Partition #4 6 = Partition #6 8 = Partition #8
L LOCATION 174 - ZONES 65-72 ZONE TYPE (8 segments, numerical data)
Location 174 contains the Zone Type for zones 65 - 72. Segment 1 is for zone 65; Segment 8 is for zone 72. Default
Zone Types are found in the table on page 19. To customize a Zone Type, see page 33.
LOCATION 175 - PARTITION SELECT, ZONES 65-72 (8 segments of feature selection data)
Location 175 is used to select the partition(s) that zones 65-72 reside in. A zone may reside in any combination of the
8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are
armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1
corresponds to zone 65 and Segment 8 corresponds to zone 72.
Segments 1 - 8:
1 = Partition #1 3 = Partition #3 5 = Partition #5 7 = Partition #7
2 = Partition #2 4 = Partition #4 6 = Partition #6 8 = Partition #8
L
LOCATION 176 - ZONES 73-80 ZONE TYPE (8 segments, numerical data)
Location 176 contains the Zone Type for zones 73-80. Segment 1 is for zone 73; Segment 8 is for zone 80. Default
Zone Types are found in the table on page 19. To customize a Zone Type, see page 33.
LOCATION 177 - PARTITION SELECT, ZONES 73-80 (8 segments of feature selection data)
Location 177 is used to select the partition(s) that zones 73-80 reside in. A zone may reside in any combination of the
8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are
armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1
corresponds to zone 73 and Segment 8 corresponds to zone 80.
Segments 1 - 8:
1 = Partition #1 3 = Partition #3 5 = Partition #5 7 = Partition #7
2 = Partition #2 4 = Partition #4 6 = Partition #6 8 = Partition #8
L LOCATION 178 - ZONES 81-88 ZONE TYPE (8 segments, numerical data)
Location 178 contains the Zone Type for zones 81-88. Segment 1 is for zone 81; Segment 8 is for zone 88. Default
Zone Types are found in the table on page 19. To customize a Zone Type, see page 33.
LOCATION 179 - PARTITION SELECT, ZONES 81-88 (8 segments of feature selection data)
Location 173 is used to select the partition(s) that zones 81 - 88 reside in. A zone may reside in any combination of
the 8 partitions. If a burglary zone resides in more than 1 partition, it will only be active when all partitions are
armed. A zone that resides in more than 1 partition will be reported to its lowest partition. Segment 1
corresponds to zone 81 and Segment 8 corresponds to zone 88.
Segments 1 - 8:
1 = Partition #1 3 = Partition #3 5 = Partition #5 7 = Partition #7
2 = Partition #2 4 = Partition #4 6 = Partition #6 8 = Partition #8
L LOCATION 180 - ZONES 89-96 ZONE TYPE (8 segments, numerical data)
Location 180 contains the Zone Type for zones 89 - 96. Segment 1 is for zone 89; Segment 8 is for zone 96. Default
Zone Types are found in the table on page 19. To customize a Zone Type, see page 33.

Other manuals for GE NetworX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX Series and is the answer not in the manual?

GE NetworX Series Specifications

General IconGeneral
ModelNetworX Series
ZonesVaries by model (e.g., 8, 16, 32, 64)
PartitionsVaries by model (typically 1-8)
KeypadsSupports multiple keypads
CommunicationPhone line, cellular, IP
Power Supply16.5 VAC
Backup Battery12VDC, 7AH
User CodesVaries by model (e.g., 48, 150, 300)
Event BufferVaries by model (e.g., 200, 500, 1000 events)
Operating Temperature0°C to 49°C (32°F to 120°F)
Communication ProtocolContact ID, SIA
WeightVaries by model
DimensionsVaries by model (e.g., 14.5" x 12.5" x 3.5")

Related product manuals