NX-8E CONTROL
49
LOC PG
DESCRIPTION DEFAULT PROGRAMMING DATA
SIREN AND SYSTEM SUPERVISION
Segment #1 (Circle numbers to program)
L
37 22
1
2
3
4
5
6
7
8
Siren sounds for telephone line cut while armed.
Siren sounds for telephone line cut while disarmed.
Siren blast at arming.
Siren blast at exit delay expiration.
Siren blast at closing kissoff.
Siren sounds during a cross-zone verification time.
Siren sounds for a tamper.
Siren blast one time for keyswitch arming, two times for disarming.
Segment #2 (Circle numbers to program)
1
2
3
4
5
6
7
8
Convert siren driver to voltage out.
Siren sounds for expander trouble (required for U.L.).
Immediate Restore by zone.
Dynamic battery test performed upon arming.
Battery missing test performed every 12 seconds.
Manual bell test performed during [r]-[4]-[4] test function.
Manual communicator test performed during [r]-[4]-[4] test function.
Box tamper enabled.
Segment #3 (Circle numbers to program)
1
2
3
4
5
6
7
8
Box Tamper report enabled.
AC Fail report enabled.
Low Battery report enabled.
Auxiliary power over current report enabled.
Siren supervision report enabled.
Telephone Line Cut report enabled.
Ground Fault Detection report enabled.
Expander trouble report enabled.
Segment #4 (Circle numbers to program)
1
2
3
4
5
6
7
8
Failure To Communicate report enabled.
Log Full report enabled.
Autotest report enabled.
Start and End Programming report enabled.
End Download report enabled.
Sensor Low Battery report enabled.
Sensor Missing report enabled.
Reserved.
Segment #5 (Circle numbers to program)
1
2
3
4
5
6
7
8
Lost Clock service LED enable.
Zone Doubling enable.
Disable on-board eight zones.
Enables two trips on the same cross-zone to activate the alarm.
Disables bypass reports for force armed zones
Silent exit.
Clock uses internal crystal.
Disable Temporal Siren on Fire (Do not disable on UL listed systems)
Segment #6
1
2
3
4
5
6
7-8
Enable 2-wire Smoke Detector.
Reserved.
Enable Zone Activity in Hours (not Days)
Enable Daylight Savings Time (DST)
Reserved
Disable Clean Me report.
Reserved.
Segment #7 - RESERVED

Other manuals for GE NetworX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX Series and is the answer not in the manual?

GE NetworX Series Specifications

General IconGeneral
ModelNetworX Series
ZonesVaries by model (e.g., 8, 16, 32, 64)
PartitionsVaries by model (typically 1-8)
KeypadsSupports multiple keypads
CommunicationPhone line, cellular, IP
Power Supply16.5 VAC
Backup Battery12VDC, 7AH
User CodesVaries by model (e.g., 48, 150, 300)
Event BufferVaries by model (e.g., 200, 500, 1000 events)
Operating Temperature0°C to 49°C (32°F to 120°F)
Communication ProtocolContact ID, SIA
WeightVaries by model
DimensionsVaries by model (e.g., 14.5" x 12.5" x 3.5")