NX-8E CONTROL
50
LOC PG
DESCRIPTION DEFAULT DATA
L
38
23 SWINGER SHUTDOWN COUNT 0 _
KEYPAD SOUNDER CONTROL
Segment #1 (Circle numbers to program)
L
39 23
1
2
3
4
5
6
7
8
Keypad sounds for Telephone Line Cut when in the Armed state.
Keypad sounds for Telephone Line Cut when in the Disarmed state.
Keypad sounds upon AC Power Failure.
Keypad sounds upon Low Battery Detection.
Keypad sounds during Cross Zone Trip Time.
Keypad sounds for Tamper Alarm.
Reserved.
Keypad sounds for expander trouble (required for UL).
SYSTEM TIMERS
Segment #1 Dynamic Battery Test duration (0-255 minutes)
0 _
Segment #2 AC Failure report delay (0-255 minutes) 5 _
Segment #3 Power Up Delay (0-60 seconds) 0 _
Segment #4 Siren Time (1-255 minutes) 8 _
Segment #5 Telephone Line Cut delay (0-255 seconds) 0 _
Segment #6 Cross Zone Time (0-255 minutes) 5 _
Segment #7 Chime Time in 50 mS increments (0-255) 3 _
Segment #8 Dialer delay ( 0-255 seconds) 0 _
Segment #9 Fire Alarm Verification Time (120-255 sec.) 0 _
Segment #10 Listen-In Time (0-255 seconds) 0 _
Segment #11 Zone Monitor Timer (0-255 Days)
L
40
23
Segment #12 – 14 Reserved
SPECIAL FEATURES
Segment #1 (Circle numbers to program)
41 23
1
2
3
4
5
6
7
8
Enables 6-digit code option. All arm/disarm/Go To Program codes require six digits
Requires valid user code entry for [r]-[9]-[8] and [r]-[9]-[9] functions to work.
Enable Auto Cancel / Abort.
Enable Walk-Test Mode.
Reserved.
Reserved.
Reserved.
Reserved.
L
42 24 GO TO PROGRAM CODE 9-7-1-3-0-0 _ _ _ _ _ _
GO TO PROGRAM CODE PARTITION AND AUTHORIZATION
Segment #1 (Circle numbers to program)
43 24
1
2
3
4
5
6
7
8
Reserved.
Enables "Go To Program Code" as an arm only code.
Enables "Go To Program Code" as an arm only after closing.
Enables "Go To Program Code" as a master arm/disarm code (can change user codes)
Enables "Go To Program Code" as an arm/disarm code.
Enables "Go To Program Code" to bypass zones.
Enables "Go To Program Code" opening and closing reports.
Reserved.

Other manuals for GE NetworX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX Series and is the answer not in the manual?

GE NetworX Series Specifications

General IconGeneral
ModelNetworX Series
ZonesVaries by model (e.g., 8, 16, 32, 64)
PartitionsVaries by model (typically 1-8)
KeypadsSupports multiple keypads
CommunicationPhone line, cellular, IP
Power Supply16.5 VAC
Backup Battery12VDC, 7AH
User CodesVaries by model (e.g., 48, 150, 300)
Event BufferVaries by model (e.g., 200, 500, 1000 events)
Operating Temperature0°C to 49°C (32°F to 120°F)
Communication ProtocolContact ID, SIA
WeightVaries by model
DimensionsVaries by model (e.g., 14.5" x 12.5" x 3.5")