EasyManua.ls Logo

GE NetworX Series - Page 57

GE NetworX Series
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NX-8E CONTROL
55
LOC PG
DESCRIPTION DEFAULT DATA
PARTITION 2 ENTRY/EXIT TIMERS
Segment #1 (Entry Time #1) 0 _
Segment #2 (Exit Time #1) 0 _
Segment #3 (Entry Time #2) 0 _
Segment #4 (Exit Time #2) 0 _
91
30
Segment #5 & #6 RESERVED
92 30 PARTITION 3, ACCOUNT CODE 10-10-10-10-10-10 _ _ _ _ _ _
PARTITION 3, FEATURE AND REPORTING SELECTION
Segment #1
1
2
3
4
Quick Arm
Re-Exit
Auto Bypass
Silent Panic
5
6
7
8
Audible Panic
Auxiliary 1
Auxiliary 2
Multi Keypress Tamper
Segment #2
1
2
3
4
LED extinguish enable
Require user code for bypassing zones
Bypass sounder alert
AC power/low battery sounder alert
5
6
7
8
Enables bypass toggle
Enables silent auto arm
Enables automatic instant
Reserved
Segment #3
1
2
3
4
Open/Close
Bypass
Restore
Trouble
5
6
7
8
Tamper
Cancel
Recent Closing
Exit Error
Segment #4
1
2-8
Late to Close / Early to Open
Reserved
93 30
Segment #5 RESERVED
PARTITION 3 ENTRY/EXIT TIMERS
Segment #1 (Entry Time #1) 0 _
Segment #2 (Exit Time #1) 0 _
Segment #3 (Entry Time #2) 0 _
Segment #4 (Exit Time #2) 0 _
94 30
Segment #5 & #6 RESERVED
95 31 PARTITION 4, ACCOUNT CODE 10-10-10-10-10-10 _ _ _ _ _ _
PARTITION 4, FEATURE AND REPORTING SELECTION
Segment #1
1
2
3
4
Quick Arm
Re-Exit
Auto Bypass
Silent Panic
5
6
7
8
Audible Panic
Auxiliary 1
Auxiliary 2
Multi Keypress Tamper
Segment #2
1
2
3
4
LED extinguish enable
Require user code for bypassing zones
Bypass sounder alert
AC power/low battery sounder alert
5
6
7
8
Enables bypass toggle
Enables silent auto arm
Enables automatic instant
Reserved
Segment #3
1
2
3
4
Open/Close
Bypass
Restore
Trouble
5
6
7
8
Tamper
Cancel
Recent Closing
Exit Error
Segment #4
1
2-8
Late to Close / Early to Open
Reserved
96 31
Segment #5 RESERVED

Other manuals for GE NetworX Series