NX-8E CONTROL
57
LOC PG
DESCRIPTION DEFAULT DATA
PARTITION 6, ENTRY/EXIT TIMERS
Segment #1 (Entry Time #1) 0 _
Segment #2 (Exit Time #1) 0 _
Segment #3 (Entry Time #2) 0 _
Segment #4 (Exit Time #2) 0 _
103 32
Segment #5 & #6 RESERVED
104 32 PARTITION 7, ACCOUNT CODE 10-10-10-10-10-10 _ _ _ _ _ _
PARTITION 7, FEATURE AND REPORTING SELECTION
Segment #1
1
2
3
4
Quick Arm
Re-Exit
Auto Bypass
Silent Panic
5
6
7
8
Audible Panic
Auxiliary 1
Auxiliary 2
Multi Keypress Tamper
Segment #2
1
2
3
4
LED extinguish enable
Require user code for bypassing zones
Bypass sounder alert
AC power/low battery sounder alert
5
6
7
8
Enables bypass toggle
Enables silent auto arm
Enables automatic instant
Reserved
Segment #3
1
2
3
4
Open/Close
Bypass
Restore
Trouble
5
6
7
8
Tamper
Cancel
Recent Closing
Exit Error
Segment #4
1
2-8
Late to Close / Early to Open
Reserved
105 32
Segment #5 RESERVED
PARTITION 7, ENTRY/EXIT TIMERS
Segment #1 (Entry Time #1) 0 _
Segment #2 (Exit Time #1) 0 _
Segment #3 (Entry Time #2) 0 _
Segment #4 (Exit Time #2) 0 _
106 32
Segment #5 & #6 RESERVED
107 32 PARTITION 8, ACCOUNT CODE 10-10-10-10-10-10 _ _ _ _ _ _
PARTITION 8, FEATURE AND REPORTING SELECTION
Segment #1
1
2
3
4
Quick Arm
Re-Exit
Auto Bypass
Silent Panic
5
6
7
8
Audible Panic
Auxiliary 1
Auxiliary 2
Multi Keypress Tamper
Segment #2
1
2
3
4
LED extinguish enable
Require user code for bypassing zones
Bypass sounder alert
AC power/low battery sounder alert
5
6
7
8
Enables bypass toggle
Enables silent auto arm
Enables automatic instant
Reserved
Segment #3
1
2
3
4
Open/Close
Bypass
Restore
Trouble
5
6
7
8
Tamper
Cancel
Recent Closing
Exit Error
Segment #4
1
2-8
Late to Close / Early to Open
Reserved
108 32
Segment #5 RESERVED

Other manuals for GE NetworX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX Series and is the answer not in the manual?

GE NetworX Series Specifications

General IconGeneral
ModelNetworX Series
ZonesVaries by model (e.g., 8, 16, 32, 64)
PartitionsVaries by model (typically 1-8)
KeypadsSupports multiple keypads
CommunicationPhone line, cellular, IP
Power Supply16.5 VAC
Backup Battery12VDC, 7AH
User CodesVaries by model (e.g., 48, 150, 300)
Event BufferVaries by model (e.g., 200, 500, 1000 events)
Operating Temperature0°C to 49°C (32°F to 120°F)
Communication ProtocolContact ID, SIA
WeightVaries by model
DimensionsVaries by model (e.g., 14.5" x 12.5" x 3.5")