NX-8E CONTROL
60
LOC PG
DESCRIPTION DEFAULT DATA
L
172 37
ZONES 57-64, ZONE TYPES 6-6-6-6-6-6-6-6 _ _ _ _ _ _ _ _
ZONES 57-64, PARTITION SELECTION (Segment 1=Zone 57 thru Segment 8=Zone 64)
Segments 1 2 3 4 5 6 7 8
173 38
Partition #1
Partition #2
Partition #3
Partition #4
Partition #5
Partition #6
Partition #7
Partition #8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
L
174 38
ZONES 65-72, ZONE TYPES 6-6-6-6-6-6-6-6 _ _ _ _ _ _ _ _
ZONES 65-72, PARTITION SELECTION (Segment 1=Zone 65 thru Segment 8=Zone 72)
Segments 1 2 3 4 5 6 7 8
175 38
Partition #1
Partition #2
Partition #3
Partition #4
Partition #5
Partition #6
Partition #7
Partition #8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
L
176 38
ZONES 73-80, ZONE TYPES 6-6-6-6-6-6-6-6 _ _ _ _ _ _ _ _
ZONES 73-80, PARTITION SELECTION (Segment 1=Zone 73 thru Segment 8=Zone 80)
Segments 1 2 3 4 5 6 7 8
177 38
Partition #1
Partition #2
Partition #3
Partition #4
Partition #5
Partition #6
Partition #7
Partition #8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
L
178 38 ZONES 81-88, ZONE TYPES 6-6-6-6-6-6-6-6 _ _ _ _ _ _ _ _
ZONES 81-88, PARTITION SELECTION (Segment 1=Zone 81 thru Segment 8=Zone 88)
Segments 1 2 3 4 5 6 7 8
179 38
Partition #1
Partition #2
Partition #3
Partition #4
Partition #5
Partition #6
Partition #7
Partition #8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8

Other manuals for GE NetworX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX Series and is the answer not in the manual?

GE NetworX Series Specifications

General IconGeneral
ModelNetworX Series
ZonesVaries by model (e.g., 8, 16, 32, 64)
PartitionsVaries by model (typically 1-8)
KeypadsSupports multiple keypads
CommunicationPhone line, cellular, IP
Power Supply16.5 VAC
Backup Battery12VDC, 7AH
User CodesVaries by model (e.g., 48, 150, 300)
Event BufferVaries by model (e.g., 200, 500, 1000 events)
Operating Temperature0°C to 49°C (32°F to 120°F)
Communication ProtocolContact ID, SIA
WeightVaries by model
DimensionsVaries by model (e.g., 14.5" x 12.5" x 3.5")