NX-8E CONTROL
69
XV. APPENDIX 1
REPORTING FIXED CODES IN CONTACT ID AND SIA
The table lists the event codes sent for the following reports (if enabled) when using CONTACT ID or SIA formats.
REPORT
CONTACT ID SIA
MANUAL TEST 601 RX
AUTOTEST 602 RP
OPEN (user number) 401 OP
CLOSE (user number) 401 CL
CANCEL (user number) 406 OC
DOWNLOAD COMPLETE 412 RS
START PROGRAM 627 LB
END PROGRAM 628 LX
GROUND FAULT 310 GF
GROUND FAULT RESTORE 310 GK
RECENT CLOSE (user number) 401 CR
EXIT ERROR (user number) 457 EE
EVENT LOG FULL 605 JL
FAIL TO COMMUNICATE 354 RT
EXPANDER TROUBLE (device number) 333 ET
EXPANDER RESTORE (device number) 333 ER
TELEPHONE FAULT 351 LT
TELEPHONE RESTORE 351 LR
SIREN TAMPER (device number) 321 YA
SIREN RESTORE (device number) 321 YH
AUX POWER OVER CURRENT (device number) 312 YP
AUX POWER RESTORE (device number) 312 YQ
LOW BATTERY (device number) 309 YT
LOW BATTERY RESTORE (device number) 309 YR
AC FAIL (device number) 301 AT
AC RESTORE (device number) 301 AR
BOX TAMPER (device number) 137 TA
BOX TAMPER RESTORE (device number) 137 TR
KEYPAD TAMPER 137 TA
KEYPAD PANIC (audible) 120 PA
KEYPAD PANIC (silent) 121 HA
DURESS 121 HA
KEYPAD AUXILIARY 1 110 FA
KEYPAD AUXILIARY 2 100 MA
RF SENSOR LOST (zone number) 381 *T
RF SENSOR RESTORE (zone number) 381 *R
SENSOR LOW BATTERY (zone number) 384 XT
SENSOR BATTERY RESTORE (zone number) 384 XR
ZONE TROUBLE (zone number) 380 *T
ZONE TROUBLE RESTORE (zone number) 380 *R
ZONE TAMPER (zone number) 137 TA
ZONE TAMPER RESTORE (zone number) 137 TR
ZONE BYPASS (zone number) 570 *B
BYPASS RESTORE (zone number) 570 *U
EARLY OPEN/LATE CLOSE 451 OK
FAIL TO CLOSE 454 CI
ZONE ACTIVITY FAULT 391 NA
ZONE ACTIVITY RESTORE 391 NS
THE NUMBER IN PARENTHESES FOLLOWING THE EVENT IS THE NUMBER THAT WILL BE REPORTED AS
THE ZONE NUMBER. IF THERE ARE NO PARENTHESES, THE ZONE WILL BE A0". SEE PAGE 71 FOR THE
DEVICE NUMBERS.
* The character transmitted in this slot will be the first character from the event code of the zone that is
bypassed or in trouble. (See locations 110 - 141)

Other manuals for GE NetworX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX Series and is the answer not in the manual?

GE NetworX Series Specifications

General IconGeneral
ModelNetworX Series
ZonesVaries by model (e.g., 8, 16, 32, 64)
PartitionsVaries by model (typically 1-8)
KeypadsSupports multiple keypads
CommunicationPhone line, cellular, IP
Power Supply16.5 VAC
Backup Battery12VDC, 7AH
User CodesVaries by model (e.g., 48, 150, 300)
Event BufferVaries by model (e.g., 200, 500, 1000 events)
Operating Temperature0°C to 49°C (32°F to 120°F)
Communication ProtocolContact ID, SIA
WeightVaries by model
DimensionsVaries by model (e.g., 14.5" x 12.5" x 3.5")