NX-8E CONTROL
70
XVI. APPENDIX 2
REPORTING ZONE CODES IN SIA OR CONTACT ID
The NX-8E has the ability to report SIA level 1 transmissions to either or both phone numbers. Each report in SIA consists
of an Event Code and a Zone or User ID. The Zone ID will be the zone number that is in alarm. The event code will come
from the chart below and be programmed in the zone type event code.
Programmed Event Code
SIA Code Description
0 HA Holdup Alarm
1 FA Fire Alarm
2 PA Panic alarm
3 BA Burglary Alarm
4 BA Burglary Alarm
5 BA Burglary Alarm
6 UA Untyped Alarm
7 BA Burglary Alarm
8 BA Burglary Alarm
9 UA Untyped Alarm
10 HA Holdup Alarm
11 MA Medical Alarm
12 PA Panic alarm
13 TA Tamper Alarm
14 RP Periodic Test
15 GA Gas Alarm
16 KA Heat Alarm
17 WA Water Alarm
18 QA Emergency Alarm
19 SA Sprinkler Alarm
20 ZA Freeze Alarm
21 KH High Temp Alarm
22 FA Manual Fire Alarm
The NX-8E has the ability to report Ademco Contact ID transmissions. Each report in Contact ID consists of an Event Code
and a Zone ID. The zone ID is the zone that created the alarm. The event code will come from the chart below and be
programmed in the zone type event code.
Programmed Event Code
Contact ID Code Description
0 122 Silent Panic
1 110 Fire Alarm
2 120 Panic alarm
3 130 Burglary Alarm
4 131 Perimeter Alarm
5 132 Interior Alarm
6 133 24 Hour Burglary
7 134 Entry Alarm
8 135 Day/Night Alarm
9 150 Non Burglary 24 Hour
10 121 Duress Alarm
11 100 Medical Alarm
12 123 Audible Panic Alarm
13 137 Tamper Alarm
14 602 Periodic Test
15 151 Gas Detected
16 158 High Temp
17 154 Water Leakage
18 140 General Alarm
19 140 General Alarm
20 159 Low Temp
21 158 High Temp Alarm
22 115 Manual Fire Alarm

Other manuals for GE NetworX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX Series and is the answer not in the manual?

GE NetworX Series Specifications

General IconGeneral
ModelNetworX Series
ZonesVaries by model (e.g., 8, 16, 32, 64)
PartitionsVaries by model (typically 1-8)
KeypadsSupports multiple keypads
CommunicationPhone line, cellular, IP
Power Supply16.5 VAC
Backup Battery12VDC, 7AH
User CodesVaries by model (e.g., 48, 150, 300)
Event BufferVaries by model (e.g., 200, 500, 1000 events)
Operating Temperature0°C to 49°C (32°F to 120°F)
Communication ProtocolContact ID, SIA
WeightVaries by model
DimensionsVaries by model (e.g., 14.5" x 12.5" x 3.5")