Tone Description
One high tone for 100 mS Time remaining indicator “A “.
One mid tone for 100 mS Time remaining indicator “B”.
One mid tone for 100 mS, off for 100 mS, one high tone for
100 mS
New alarm alerts for the same partition.
One high tone for 100 mS, off for 100 mS, one mid tone for
100 mS, off for 100 mS, one high tone for 100 mS
New alarm alerts for a different partition.
Continuous on/off high tone every 100 mS; will stop after a
digit is received
System waiting for access PIN.
One low tone for 200 mS (if enabled) Anti lock-up
One mid tone for 500 mS Acknowledgement to level change command.
One mid tone for 250 mS, off for 250 mS, one mid tone for
250 mS, off for 250 mS, one mid tone for 250 mS
Error tone
One low tone for 100mS Relay / Output turned ON, or
Positive Status response, or
partition 1 armed.
One low tone for 100mS; off for 200mS; one low tone for
100 mS
Relay / Output turned OFF, or
Negative Status response, or
partition 1 disarmed.