LOCATION 1 - CALLBACK ACCESS CODE (default = 123456) (6 segments, feature selection
data)
Location 1 contains the access code used to start a listen-in session when the NX-534E is in a
callback mode. The callback access code can be up to a maximum of 6 digits. The valid entries are 0-
15 (10 = *, 11 = , 12 = none, 13 thru 15 = any digit). If less than six digits are desired, program a
“15” at the end of the desired code. If location 1 contains a “15”, any digit will access the NX-534E.
If segment 1 contains a “12”, no access code is required.
LOCATION 2 - LINE HOLD MODE ACCESS DIGIT (default = 15(F)) (1 segment, numerical data)
Location 2 is used to determine the line-hold access digit. This digit is required to start a two-way
session if line-hold mode is used. Valid entries are: 0 - 15 (10 = *, 11 = #, 12 = none, 13 thru 15 =
any digit). If location 2 contains a “15”, any digit will access the NX-534E. If location 2 contains a
“12”, no access digit is required.
LOCATION 3 - TIMING OPTIONS (8 segments, numerical data)
Segment 1 - Line hold timeout (default = 60 seconds)
Location 3, segment 1 determines how long the NX-534E will wait for the line-hold digit
programmed in location 2 while in the line-hold mode. After a digit is pressed, the timer will reset. If
the digit is not received during this time, the NX-534E will hang-up (disconnect). This time is
programmable from 10 to 255 seconds for each digit.
Segment 2 - New trip hang-up time (default = 20 seconds)
Location 3, segment 2 is used to determine where the NX-534E will set the session timer when a new
trip is received on the same partition during a two-way session. This time is programmed from 1 to
255 seconds, and will be extended if there is any activity from the central station. If an alarm occurs
in the same partition, pressing a key in this time period will extend the session timer. If the alarm is
in a different partition, the timer will be reduced automatically and will now allow the timer to be
restarted.
Segment 3 - Callback window timer (default = 5 minutes)
Location 3, segment 3 will determine the amount of time, in 1-minute increments, the NX-534E will
wait for a callback when enabled in location 0, segment 1 or initiated by the central station (see also
“control levels” on page 6). Possible increments are 1 to 255 minutes.
Segment 4 - Wrong pin entries (default = 12)
Location 3, segment 4 determines the maximum number of attempts that can be made to enter valid
access codes for callback and call-in features. Refer to location 0, segments 1 and 6. Valid entries are
6 - 255 attempts. Default is set for 12 attempts.
Segment 5 - Session inactivity hang-up time (default = 90 seconds)
Location 3, segment 5 is used to determine how long the NX-534E will remain on the phone line
with no activity from the central station. This time can be programmed from 30 to 255 seconds.