EasyManua.ls Logo

GE RSTi-EP - 3.5 Current Demand and Power Supply

GE RSTi-EP
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 7. Detailed Descriptions of EP-19xx Modules
GFK-2956A November 2017 29
Process Data
Byte
Bit
Description
Status
0
0
Safety input 0
0 - inactive, 1 - active
1
Safety input 1
0 - inactive, 1 - active
2
Auto Start
0 - inactive, 1 - active
3
Man Start
0 - inactive, 1 - active
4
Safety input 0 / channel 1
0 - inactive, 1 - active
5
Safety input 0 / channel 2
0 - inactive, 1 - active
6
Safety input 1 / channel 1
0 - inactive, 1 - active
7
Safety input 1 / channel 2
0 - inactive, 1 - active
1
0
24 V Safe Output
0 - inactive, 1 - active
1
Reserved
2
24 V DC
0 - no power feed, 1 - power feed-in pending
3-7
Reserved
2
0-7
Reserved
3
0-7
Reserved
Standard data format
Diagnostic Data
Name
Bytes
Bit
Description
Default
Error indicator
0
0
Module error
1
Internal error
2
External error
3
Channel error
4
Reserved
0
5
Power supply fault
6
Reserved
0
7
Parameter error
0
Module type
1
0
Module Type
0x03
1
2
3
4
Channel information available
1
5
Reserved
0
6
Reserved
0
7
Reserved
0
Error byte 2
2
0
Failure Code
Name
Bytes
Bit
Description
Default

Table of Contents