Security Pro 500
19
Testing Sirens
The purpose of this weekly test is to verify that the panel is activating sirens with the appropriate 
warning sounds.
¾
To perform an alarm siren warning sound test:
1. Contact the central monitoring station to inform them that you will be activating alarms and 
they should not dispatch authorities.
2. Activate alarms of each type (fire, police, auxiliary), one at a time.
3. Listen for the appropriate siren sound when each alarm is activated (see the “Alarm Sound” 
table).
Troubleshooting Your security system uses a variety of different alarm sirens, status beeps, and trouble beeps to 
communicate with you. The next few pages describe the different sounds and what they mean. 
Try to familiarize yourself with the differences. You will hear some sounds each time you tell 
your security system to do something, like arm or disarm. Some sounds you will hear only when 
there is a problem with the system, like a low battery. Other sounds you will only hear in an 
emergency. Getting to know your system sounds allows you to react quickly and appropriately.
Table 1: Testing Sensors and Zones
Device Test Procedure Touchpad Result
Touchpads Send a:
• Police panic alarm,
• Fire panic alarm, and 
• Auxiliary panic alarm.
• Touchpad Panic POLICE OK
• Touchpad Panic FIRE OK
• Touchpad Panic AUXILIARY OK
• POLICE PANIC OK
• FIRE PANIC OK
• AUXILIARY PANIC OK
Wireless Touchpads Press the Bypass key. • Zones nn OK
• Touchpad nn OK
Keychain Touchpads Press and hold Lock and Unlock simultaneously for 3 
seconds.
•Zones nn OK
•SENSOR nn OK
OR
• Touchpad Panic POLICE  OK
• POLICE PANIC OK
Panic buttons Press and hold the appropriate panic button(s) for 3 full 
seconds.
•Zones nn OK
•SENSOR nn OK
Door/window sensor Open the secured door or window. • Zones nn OK
•SENSOR nn OK
Smoke detector Press and hold the test button until the system sounds 
transmission beeps.
•Zones nn OK
•SENSOR nn OK
Motion detector Avoid the motion detector’s view for 5 minutes, then 
enter its view.
•Zones nn OK
•SENSOR nn OK
Rate-of-Rise Heat Detector
(Not UL investigated)
Rub your hands together until warm, then place one 
hand on the detector for 30 seconds.
•Zones nn OK
•SENSOR nn OK
Shock sensor
(Not UL investigated)
Tap the glass twice, away from the sensor.  Wait at least 
30 seconds before testing again.
•Zones nn OK
•SENSOR nn OK
Glass guard sensor
(Not UL investigated)
Tap the glass 3 or 4 inches from the sensor. • Zones nn OK
•SENSOR nn OK
Freeze sensor
(Not UL investigated)
Apply an ice cube wrapped in plastic to the sensor.
Do not allow the sensor to get wet.
•Zones nn OK
•SENSOR nn OK