4.3 Alarm #05 - TAL product feed
Temp.< min
Separation “Stop”
Text display Possible causes Action
Product too cold before preheater
•
Check settling tank temperature.
•
Setpoint TAL set too high.
•
Temperature of heating medium too
low.
• Check heating medium tempera-
Temperature controller defective.
•
Check temperature controller.
Controller setting or function not o.k.
• Check controller setting and func-
Line compensation at controller not
correctly adjusted.
• Check line compensation at con-
•
•
Help text on the control system
Step 1 Acknowledge fault
HEL P
Step 2
Press key >F1<
Help on alarm
Press key >HOME< back
Page 1
PRODUCT TEMP.- MIN
Please check:
Settling tank temperature
Feed capacity
Page 2
Setpoint TAL
Temp. heating medium
Temp. controller
Switching stages elect.
Page 3
Preheater
PT100 sensor
Back with ENTER