EasyManua.ls Logo

GEA D 10 - Page 48

GEA D 10
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
48 8555-9201-000 / 0109
Mechanical Separation / GEA Westfalia Separator
4.3 Alarm #05 - TAL product feed
Temp.< min
Separation “Stop”
Text display Possible causes Action
Product too cold before preheater
Check settling tank temperature.
Feed capacity too high.
Check feed capacity.
Setpoint TAL set too high.
Check setpoint TAL.
Temperature of heating medium too
low.
Check heating medium tempera-
ture.
Temperature controller defective.
Check temperature controller.
Controller setting or function not o.k.
Check controller setting and func-
tion.
Line compensation at controller not
correctly adjusted.
Check line compensation at con-
troller.
Preheater soiled.
Check preheater.
PT 100 sensor defective.
Check sensor.
Help text on the control system
ENT E R
Step 1 Acknowledge fault
HEL P
Step 2
Press key >F1<
Help on alarm
Press key >HOME< back
Page 1
PRODUCT TEMP.- MIN
Please check:
Settling tank temperature
Feed capacity
->
Page 2
Setpoint TAL
Temp. heating medium
Temp. controller
Switching stages elect.
->
Page 3
Preheater
PT100 sensor
Back with ENTER
F1