8555-9201-000 / 0109 49
Mechanical Separation / GEA Westfalia Separator
4.4 Alarm #06 - TAH product feed
Temp. >max
Separation - Stop
Text display Possible causes Action
•
•
Setpoint TAH set too low.
•
Controller setting or function not o.k.
• Check controller setting and func-
Line compensation at controller not
correctly adjusted.
• Check line compensation at control-
Temperature controller defective.
•
Check temperature controller.
PT 100 sensor defective.
•
Help text – Information on the control system
Step 1 Acknowledge fault
HEL P
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
PRODUCT TEMP. MAX
Please check:
Control valve
Feed capacity
Page 2
Setpoint TAH
Switching stages electr.
Temperature controller
PT100 sensor
Seite 3
Back with ENTER