Mechanical Separation / GEA Westfalia Separator
4.5 Alarm #07 - Ejection monitoring
Eject. curr.< offset
Separation “Stop”
Alarm#07 ENTER
Textdisplay Possible causes Action
Operating water valve V3 is defective.
Check bowl hydraulic function with
operating water valve V3.
Connector on operating water valve V3
is loose.
Check connector on operating
water valve V3.
Offset setting for ejection current ad-
justed too high.
Check offset setting.
Water volume at V3 too low.
Check water volume.
Monitoring time T28 too short.
Check T28.
Current evaluation defective.
Check current transformer electri-
callly.
Filter insert in strainer at solenoid block
soiled.
Check filter insert.
Clutch shoes worn or oily.
Check clutch shoes.
Help text Information on the control system
ENT E R
Step 1 Acknowledge fault.
HEL P
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
EJECTION MONITORING
Please check:
Bowl function
Hydraulic with V3
->
Seite 2
Plug-in valvel V3
Current offset
Setting
Water volume
->
Page 3
T28
Current transformer electr.
Prestrainer
Back with ENTER
F1