8555-9201-000 / 0109 51
Mechanical Separation / GEA Westfalia Separator
4.6 Alarm #08 - LAHH sludge tank
Sludge tank - full
Separation “Stop”
Text display Possible causes Action
Sludge pump does not function.
•
•
Product overflow due to excessively
high clean oil discharge pressure.
• Check valves in the clean oil line
Closing water pulse T06 too long.
•
Polyamide gasket in bowl top defec-
tive.
• Check polyamide gasket in bowl
top; replace if necessary.
Gaskets in bowl defective.
•
Level switch LSHH soiled or defective.
•
Help text – Information on control system
Step 1 Acknowlede fault
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
LSHH – SLUDGE TANK
Please check:
Sludge pump
Bowl hydraulics
Seite 2
Valves in the
clean oil line
Position V7
Closing water pulse
Page 3
Polyamide gasket
Switch LSHH
Back with ENTER