8555-9201-000 / 0109 51
Mechanical Separation / GEA Westfalia Separator
4.6 Alarm #08 - LAHH sludge tank
LAHH SLUDGE TANK
Sludge tank - full
Separation “Stop”
Alarm#08 ENTER
Text display Possible causes Action
Sludge pump does not function.
Check sludge function.
Bowl open.
Check bowl hydraulics.
Product overflow due to excessively
high clean oil discharge pressure.
Check valves in the clean oil line
and position V7.
Closing water pulse T06 too long.
Check T06.
Polyamide gasket in bowl top defec-
tive.
Check polyamide gasket in bowl
top; replace if necessary.
Gaskets in bowl defective.
Check gaskets.
Level switch LSHH soiled or defective.
Check level switch LSHH.
Help text Information on control system
ENT E R
Step 1 Acknowlede fault
HEL P
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
LSHH – SLUDGE TANK
Please check:
Sludge pump
Bowl hydraulics
->
Seite 2
Valves in the
clean oil line
Position V7
Closing water pulse
->
Page 3
Polyamide gasket
Switch LSHH
Back with ENTER
F1