EasyManua.ls Logo

GEA D 10 - Page 52

GEA D 10
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
52 8555-9201-000 / 0109
Mechanical Separation / GEA Westfalia Separator
4.7 Alarm #09 - feed pump fault
FEED PUMP FAULT
Motor protection
Separation “Stop”
Alarm#09 ENTER
Text display Possible causes Action
Feed pump overloaded.
Check protective switch and current
consumption.
Feed pump mechanically blocked.
Check pump.
Valve in the suction line of the feed
pump closed.
Check valves.
Feed temperature
Check feed temperature.
Filter in feed line soiled.
Check filter.
Electrical connections incorrect.
Check electrical connections and
wiring.
Help text Information on the control system
ENT E R
Step 1 Acknowledge fault
HEL P
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
FEED PUMP FAULT
Please check:
Protective switch
Current consumption
->
Page 2
Pump
Valves
Feed temperature
Filter
->
Page 3
Electr. connections
Wiring
Back with ENTER
F1