52 8555-9201-000 / 0109
Mechanical Separation / GEA Westfalia Separator
4.7 Alarm #09 - feed pump fault
FEED PUMP FAULT
Motor protection
Separation “Stop”
Alarm#09 ENTER
Text display Possible causes Action
Feed pump overloaded.
• Check protective switch and current
consumption.
Feed pump mechanically blocked.
•
Check pump.
Valve in the suction line of the feed
pump closed.
• Check valves.
Feed temperature
•
Check feed temperature.
Filter in feed line soiled.
•
Check filter.
Electrical connections incorrect.
• Check electrical connections and
wiring.
Help text – Information on the control system
ENT E R
Step 1 Acknowledge fault
HEL P
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
FEED PUMP FAULT
Please check:
Protective switch
Current consumption
->
Page 2
Pump
Valves
Feed temperature
Filter
->
Page 3
Electr. connections
Wiring
Back with ENTER
F1