8555-9201-000 / 0109 53
Mechanical Separation / GEA Westfalia Separator
4.8 Alarm #10 - Sludge pump fault
Program stop
Text display Possible causes Action
Sludge pump overloaded.
Check protective switch and current
consumption.
Sludge pump mechanically blocked.
Check pump.
Valve in the pressure line closed.
Check valves.
Pipe on the suction and pressure side
of the pump blocked.
Check pipes.
Electrical connections incorrect.
Check electrical connections and
wiring.
Help text information on the control system
ENT E R
Step 1 Acknowledge fault
HEL P
Step 2
Press key >F1<
Help on alarm
Key >HOME<back
Page 1
SLUDGE PUMP FAULT
Please check:
Protective switch
Current consumption
->
Page 2
Pump
Valves
Pipes
Electr. connections
->
Page 3
Wiring
back with ENTER