4.9 Alarm #11 - Vibration stage 1 (option)
VIBRATION STAGE 1:
Motor off after T25
Alarm#11 ENTER
Text display Possible causes Action
Limit value 1 longer than T25.
Check T25.
Uneven solid desposits in the bowl.
Check solids space and polyamide
gasket of the bowl top.
Vibo sensor has tripped.
Check sensor fastening.
Limit value 1 set too low.
Check setting.
Bowl not correctly mounted or wrong
parts from other bowl.
Open and clean the bowl and mount
in accordance with the manual.
CAUTION!
Use only parts with identical
serial number.
External vibrations
Check foundation fastening ar-
rangement.
Help text information on the control system
ENT E R
Step 1 Acknowledge fault
HEL P
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
VIBRATION STAGE 1:
Please check:
Timer 25
Solids space
->
Page 2
Polyamide gasket
Sensor fastening
Limit value 1
Correct bowl parts
->
Page 3
Foundation fastening
Back with ENTER