4.10 Alarm #12 - Vibration stage 2 (option)
Separator “Off”
Text display Possible causes Action
Limit value 2 set too low.
•
Uneven solid desposits in the bowl.
• Check solids space and polyamide
Vibro sensor has tripped.
•
Bowl not correctly mounted, damaged
or wrong parts from other bowl.
• Open and clean the bowl and mount
in accordance with the manual.
• Use only parts with identical
• Check foundation fastening ar-
Help text – information on the control system
Step 1 Acknowledge fault
HEL P
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
VIBRATION STAGE 2:
Please check:
Limit value 2
Solids space
Page 2
Polyamide gasket
Sensor fastening
Correct bowl
parts
Page 3
Foundation fastening
Back with ENTER