Mechanical Separation / GEA Westfalia Separator
4.11 Alarm #13 - Fault series operation (option)
Line or
Pre-selection not ok
Text display Possible causes Action
“SERIES” key not pressed on both
controls.
• Press “SERIES” key on both con-
Both separators not ready for opera-
tion
• Check operational readiness of the
Line (MPI) for series operation defec-
tive or missing.
• Check line (MPI).
Switch position on MPI bus connector
not correct.
Switch position is at “OFF”.
• Check switch position. Switch posi-
tion must be “ON”, terminator is ac-
tive.
Note :
MPI = Multi Point Interface
Help text – information on the control system
Step 1 Acknowledge fault
HEL P
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
FAULT SERIES OPERATION
Please check:
Series button pressed
On both devices
Page 2
Operational readiness
of both separators
MPI line
Page 3
MPI bus connector