8555-9201-000 / 0109 57
Mechanical Separation / GEA Westfalia Separator
4.12 Alarm #15 - WMS system fault
WMS SYSTEM FAULT
Too much water
Separation “Stop”
Alarm#15 ENTER
Text display Possible causes Action
Water content in feed too high.
Check product feed.
Too much filling water.
T02 set too long.
Check T02.
Filling water valve V2 leaks.
Check filling water valve V2.
Incorrect setting on evaluating relay.
Check setting on evaluating relay.
T22 set too short.
Check setting T22.
If necessary, extend T22 during this
phase.
Help text information on the control system
ENT E R
Step 1 Acknowledge fault
HEL P
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
WMS SYSTEM FAULT
Please check:
Water content in
feed
->
Page 2
Filling water qty. T02
Valve V2
Setting on
evaluating relay
->
Page 3
Setting Z22
back with ENTER
F1