58 8555-9201-000 / 0109
Mechanical Separation / GEA Westfalia Separator
4.13 Alarm #18 - Bowl monitoring
Current too high
during TIMER 06
Text display Possible causes Action
Closing water pulse T06 too long,
bowl has opened.
• Check T06.
Water pressure for hydraulics during
T06 too high, bowl has opened.
• Check water pressure with open
valve V3.
Valve V3 is soiled, catches, remains
open too long.
• Check valve V3.
•
•
•
Deselect function if required.
Help text – information on the control system
Step 1
Acknowledge fault
HEL P
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
BOWL MONITORING
Please check:
Timer 06
Water pressure for hydraulics
Page 2
Function V3
Current value
Page 3
back with ENTER