Mechanical Separation / GEA Westfalia Separator
4.15 Alarm #21 - WMS sensor fault (option)
WMS SENSOR FAULT
During WMS CHECK
During TIMER 45
Alarm#21 ENTER
Text display Possible causes Action
WMS sensor soiled.
Check WMS sensor.
WMS sensor malfunction.
Check WMS sensor.
Water discharge valve V6 doesn’t
open.
Check function V6.
Not sufficient water during T45
Check water volume.
T45 too short.
Check T45.
T02 too short (HFO).
Check T02.
Deselect function if required.
Help text information on the control system
ENT E R
Step 1 Acknowledge fault
HEL P
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
WMS SENSOR FAULT
Please check:
WMS sensor
soiled
->
Page 2
Function WMS
Sensor
Function V5/V6
Water volume
->
Page 3
Timer 45
Timer 02 (HFO)
too short
back with ENTER
F1