8555-9201-000 / 0109 61
Mechanical Separation / GEA Westfalia Separator
4.16 Alarm #22 - Sludge pump running time too long
TIME TOO LONG
In TR3 hours
Text display Possible causes Action
Time recording TT2 set too short.
•
Check time recording TR2.
•
Check bowl function/hydraulics.
Water content in feed too high.
• Dewater product upstream of sepa-
Slight product overflow due to clean
oil discharge pressure set too high.
• Check clean oil discharge setting.
Sludge pump output too low.
• Check pump function.
Note :
Time recording zero position. Factory setting 24h.
Help text – information on the control system
Step 1 Acknowledge fault
HEL P
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
SLUDGE PUMP RUNNING
TIME TOO LONG
Please check:
TR2 time recording
Page 2
Bowl function
Bowl leakage
Water content in
product
Page 3
Pump function
back with ENTER