64 8555-9201-000 / 0109
Mechanical Separation / GEA Westfalia Separator
4.19 Warning #28 - Warning water content
WARNING
WATER CONTENT
Alarm#28 ENTER
Text display Possible causes Action
Heightened water content in product
feed.
• Pre-dewater product and check
cause.
T47 set too long, does not correspond
to throughput capacity.
• Check setting T47.
Filling water valve V2 leaks.
•
Check valve V2.
•
Deselect function if required.
Help text – information on the control system
ENT E R
Step 1 Acknowledge fault
HEL P
Step 2
Press key >F1<
Help on alarm
Key >HOME< back
Page 1
WARNING
Water content
Please check:
Water content in product
->
Page 2
Setting timer 47
and feed capacity
Check whether V2 leaks
->
Page 3
back with ENTER
F1