24
Swim Spa Solution™
in.xe™ programming fi eld options
In the event where none of the pre-determined low level
program confi gurations built into the in.xe™ system suits your spa
equipment assembly, it's possible to customize the in.xe™ system
by manually entering key parameter settings.
To access this menu, press and hold Prog. for 30 seconds. Use Up
or Down key to choose setting. Press Prog. key to advance to the
next parameter.
programming the in.xe™
Parameter Display Options Description
Output 1A
--,1H,1L,2H,2L,3H,3L,4H,
4L,P5,BL,CP,O3,L2,H
Accessory connected to the relay of Output 1A
Output 1B
--,1H,1L,2H,2L,3H,3L,4H,
4L,P5,BL,CP,O3,L2,H
Accessory connected to the relay of Output 1B
Output 2
--,1H,1L,2H,2L,3H,3L,4H,
4L,P5,BL,CP,O3,L2,H
Accessory connected to the relay of Output 2A
Output 3
--,1H,1L,2H,2L,3H,3L,4H,
4L,P5,BL,CP,O3,L2,H
Accessory connected to the relay of Output 3A
Output 4
--,1H,1L,2H,2L,3H,3L,4H,
4L,P5,BL,CP,O3,L2,H
Accessory connected to the relay of Output 4A
Output 5 --, H Accessory connected to the relay of Output 5A
--
--
--
--
--
--
Output 2Output 1 Output 3 Output 4
Output Direct
Output 5 or
Heater