37
Swim Spa Solution Er1 error condition ow chart
The communication between the MASTER and the SLAVE pack doesn't work.
Replace
communication
cable
Run a visual
inspection of
the cable.
Is it physically
damaged?
yes
no
Run a visual ins-
pection of both
CO connectors to
look for bent pins
(you should see
8 straight pins).
Are there bent
pins?
Flow chart
Verify the
connection
between the
2 packs. Ensure
that the in.link
connectors
are fully recess
in the CO
connector of
both packs.
Try straightening
the pin or replace
the pack.
yes
no
Try replacing the
communication
first. If is still
doesn’t work
replace the packs
one at a time.