6. Look to be sure the support device is secure against the cylinder end. Then,
stop the loader engine, remove the key and leave the operator’s compartment.
7. Stop the engine, and exit the machine.
Disengagement
The safest method of installing and removing
the lift arm support device requires two
people – one person inside the loader and another person outside
the loader to disengage the support device.
Important: With the key switch OFF and the solenoid valve working properly, the
lift arm will stay raised when the lift control is moved to lower the lift arm. If the
valve does not hold the lift am and it begins to lower do not leave the operators
compartment. Instead, lower the lift arm and exit the machine. Then, contact
your Gehl dealer immediately to determine why the lift arm lowers while the key
switch is OFF.
To return the lift arm support device to its storage position:
1. Start the engine;
2. Raise the lift arm fully;
3. Stop the engine;
4. Verify that the lift arm is being held in
the raised position by the safety inter-
lock system.
5. To store the support device, have an
assistant raise it up until it contacts the
lift arm. Reinstall the lynch pin through
the welded steel post on the lift arm
(Figure 4).
ACCESSORY Plug
The 12-V accessory plug is located at the bottom of the right instrument panel.
Dome Light
The dome light is located on the right side of the ROPS/FOPS headliner. Push on
the dome light to switch it on.
WARNING
Figure 4 Lift Arm Support
Device Storage Location

Table of Contents