EasyManua.ls Logo

Gemalto Cinterion - Storage Conditions; Table 18: Storage Conditions

Gemalto Cinterion
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cinterion
®
Java Terminals Hardware Interface Description
4.3 Storage Conditions
44
EHSxT_BGS5T_HID_v02 2014-05-23
Confidential / Preliminary
Page 38 of 70
4.3 Storage Conditions
The conditions stated above are only valid for devices in their original packed state in weather
protected, non-temperature-controlled storage locations. Normal storage time under these
conditions is 12 months maximum.
Table 18: Storage conditions
Type Condition Unit Reference
Air temperature: Low
High
-30
+75
°C ETS 300 019-2-1: T1.2, IEC 60068-2-1 Ab
ETS 300 019-2-1: T1.2, IEC 60068-2-2 Bb
Humidity relative: Low
High
Condens.
10
90 at 30°C
90-100 at 30°C
%---
ETS 300 019-2-1: T1.2, IEC 60068-2-56
Cb
ETS 300 019-2-1: T1.2, IEC 60068-2-30
Db
Air pressure: Low
High
70
106
kPa IEC TR 60271-3-1: 1K4
IEC TR 60271-3-1: 1K4
Movement of surrounding air 1.0 m/s IEC TR 60271-3-1: 1K4
Water: rain, dripping, icing and
frosting
Not allowed --- ---
Radiation: Solar
Heat
1120
600
W/m
2
ETS 300 019-2-1: T1.2, IEC 60068-2-2 Bb
ETS 300 019-2-1: T1.2, IEC 60068-2-2 Bb
Chemically active substances Not
recommended
IEC TR 60271-3-1: 1C1L
Mechanically active substances Not
recommended
IEC TR 60271-3-1: 1S1
Vibration sinusoidal:
Displacement
Acceleration
Frequency range
1.5
5
2-9 9-200
mm
m/s
2
Hz
IEC TR 60271-3-1: 1M2
Shocks:
Shock spectrum
Duration
Acceleration
semi-sinusoidal
1
50
ms
m/s
2
IEC 60068-2-27 Ea