上海鲍麦克斯电子科技有限公司 AS系列数控交流伺服系统说明书
7
134 0~1024 90
Trimming point of pedal
135 0~1024 300
Footer lifting point of pedal
136 0~1024 460
Neutral point of pedal
137 0~1024 480
Motor running point of pedal in low
speed.
138 0~1024 580
Accelerated point of pedal
139 0~1024 962
Max speed point of pedal
Figure 4-1 shows the
specific setting method
13E 1~800 100
After trimmer the press lifter delay time (dial line)
140 0/1 1
Soft start at the first cycle of power ON. 0: Disable 1: Enable
143
0/1/2/
3
0
Special mode:
0: Normal Mode
1: Simply sewing mode
2: Motor initial angle measurement (Do not remove the belt)
3: Automatically setting the pulley ratio by the CPU. (synchronizer is
necessary and the belt not removed)
144 0~31 0
Feedforward torque of motor:
0: Normal functions
1-31: Feedforward torque level
149 0~10 0
The time of chopping on for the presser foot slow down (uint is
100us)
150 1~100 1
The proportion coefficient of the stitches counter
151 1~9999 1
Maximum stitches of the counter
152 0~6 0
Count mode selection (For Bobbin Thread)
0: The counter is invalid
1: Count up by stitches. When count over, counter will be auto-
reset.
2: Count down by stitches. When count over, counter will be auto-
reset.
3: Count up by stitches. When count over, motor stops and the
counter must be reset by the external switch or the P key on the
panel.
4: Count down by stitches. When count over, motor stops and the
counter must be reset by the external switch or the P key on the
panel.
5: Count up by trimming. When count over, panel alarms and motor
stops after trimming.
6: Count down by trimming. When count over, panel alarms and
motor stops after trimming.