Appendix C– DTR Remote M&C Protocol CG-6073 (Rev R, Jun, 2012)
46
SPU SERIAL LINK STATS
Path: / STATUS SPU-DIAG
Type: Executable
Syntax: SPU-DIAG
Notes: Displays the SPU RS422 serial link statistics separated by destination (MCU and
DSP): Timeouts – the CPU did not get a response within 100mSec. Errors –
unexpected responses that do not match the internal protocol. % of Total –
indicates the percentage of errors plus timeouts versus the total number of
commands. Linklosses – counts the number of failures to establish communication
with the MCU or DSP processors. Total – sum total of commands sent.
START
Path: / CONFIGS MONOPULSE
Type: Executable
Syntax: START
Notes: START monopulse operation; to stop, use EXIT followed by a carriage return. It
stops automatically if and when a fault is set. After stopping, in either case, the
mute switch is enabled. NOTE: Only usable via the M&C
STATUS (v1.16.51 or later)
Path: / STATUS
Type: Sub Menu
Syntax: STATUS
Notes: The STATUS menu contains useful diagnostic tools. The SPECTRAL DISPLAY
option is accessed from this menu, as are other tools, such as a I/O status and the
message log. This parameter was called DIAGS prior to v1.16.51.
STORE BEACONS
Path: / CONFIGS BEACONS STORE-BEACONS
Type: Sub Menu
Syntax: STORE-BEACONS
Notes: Executing each item in this menu will STORE CURRENT values of the following
parameters as a BEACON state: FREQUENCY, INPUT ATTEN, POL SELECT, FILTER,
SLOPE, VOLT RANGE, MIN REF LVL, and ATTENUATION.