Appendix CDTR Remote M&C Protocol CG-6073 (Rev R, Jun, 2012)
48
SYSTEM MEMORY
Path: / CONFIGS MEMORY
Type: Sub Menu
Syntax: MEMORY
Notes: The MEMORY menu contains commands relating to the storage of system
parameters that are stored in nonvolatile RAM (NVRAM).
TESTS
Path: / TESTS
Type: Sub Menu
Syntax: TESTS
Notes: The TESTS menu provides system integrity tests. These tests are primarily intended
for GDST factory testing. USE OF SOME TESTS MAY OBSCURE REAL TIME DATE,
AND OTHERS MAY TEMPORARILY AFFECT THE PERFORMANCE OF THIS
RECEIVER.
TROUBLESHOOT
Path: / STATUS TROUBLESHOOT
Type: Executable
Syntax: TROUBLESHOOT
Notes: This is a diagnostic tool to provide online help information on the current faults.
VOLTAGE RANGE
Path: / CONFIGS OPERATION ANALOG-OUTPUTS DAC1 DAC1-RANGE
Type: Data Editor
Syntax: DAC1-RANGE [= n] | [D]
Range: Integer: 0 .. 2
0 0 to +10
1 -10 to +10
2 -5 to +5
Notes: The DC VOLTAGE RANGE of the Digital to Analog Converter. Used to represent the
signal level as a tracking voltage.

Table of Contents