Appendix C– DTR Remote M&C Protocol CG-6073 (Rev R, Jun, 2012)
66
L Start Monopulse diagnostic mode (Monopulse units only). The port
does not have to be in control but all faults must be cleared. The
mode exits if a fault is set. Use Xn to stop.
Usage: Ln
n is 0 or 1 and determines whether the monopulse mute switch is turned off
or on, respectively.
Output:+dddddd +eeeeee +ffffff +gggggg
dddddd=quadrant #1 level in hex.
eeeeee=quadrant #2 level in hex.
ffffff=quadrant #3 level in hex.
gggggg=quadrant #4 level in hex.
M Start Monopulse mode (Monopulse units only). The port must be in
control and all faults must be cleared. The mode exits if control is lost
or a fault is set. Use Xn to stop.
Usage: Mn x x x x
n is 0 or 1 and determines whether the monopulse mute switch is turned off
or on, respectively, and the x's are ignored but must be present.
Output:+ddddd +eeeee +fffff
ddddd=error vector 1 in hex.
eeeee=error vector 2 in hex.
fffff=sum of phase vectors in hex.
N See DTR keyword N
S See DTR keyword S
V Gets or sets the FFT sample averaging parameter. This is not a native
TRL command, but was added to allow the 7200 ACU TRL shell to set
FFT averaging. See / CONFIGS OPERATION AVERAGING
Usage: V[n]
n is the averaging value; if not specified, the current value is returned in four
digits on the next line.
W Gets or sets the digital filter index parameter. This is not a native TRL
command, but was added to allow the 7200 ACU TRL shell to set the
bandpass filter. See / CONFIGS OPERATION FILTER
Usage: W[n]
n is the filter index; if not specified, the current value is returned in four
digits on the next line.
X Exits Monopulse mode (Monopulse units only)
Usage: Xn
n is 0 or 1 and determines whether the monopulse mute switch is turned off
or on, respectively.