Appendix CDTR Remote M&C Protocol CG-6073 (Rev R, June, 2012)
67
Y Gets or sets the Monopulse data transfer rate. (Monopulse units only)
Usage: Y?|[-]n[n...] m
"Y?" queries the millisecond interval of the monopulse data transmission.
"Yn m" sets the interval, where n is -1 or the transfer interval in 1228
counts per 4ms and m is ignored but must be present. The valid range for n
is -1 to 3070000 (value is forced into this range).
n / 1228 * 4 ms is the minimum interval between sets of monopulse data
n < 1228 = 0 ms, n = 1228 = 4 ms, and n >= 3070000 = 10 seconds
n = -1 specifies an infinite interval; new data is sent only after receiving a
carriage return.
Example: Y1229 n/a
n: 1229 / 1228 * 4 = 4 ms interval
m: "n/a" is ignored