Appendix C– DTR Remote M&C Protocol CG-6073 (Rev R, Jun, 2012)
34
MODE
Path: / CONFIGS MONOPULSE
Type: Data Editor
Syntax: MODE [= n] | [D]
Range: Integer: 0 .. 1
0 Vectors
1 Levels
Notes: MODE sets the type of monopulse output of START, either two error vectors with
sum for normal operation or four phase levels for diagnostics. All output is in
hexadecimal:
0:VECTORS reply:
"[+|-]ddddd [+|-]eeeee -fffff" where d and e units are |dBm/10000| and f units
are |dBm/1000| (range 0 to -262.143 dBm)
1:LEVELS reply:
"+dddddd +eeeeee +ffffff +gggggg" where units are |dBm/1000|
NOTE: Also set by M&C in TRL-Emulation
NCO OFFSET
Path: / CONFIGS MEMORY CALIBRATION NCO
Type: Data Editor
Syntax: NCO [= n] | [D]
Range: Real: -6000.000 .. 99999.999
Notes: Adjusts the frequency of the Numerically Controlled Oscillator (NCO) on the SPU.
NEWLINE
Path: / CONFIGS COMM-PARAM PORT-1 NEWLINE
Type: Data Editor
Syntax: NEWLINE [= n] | [D]
Range: Integer: 0 .. 1
0 Disabled
1 Enabled
Notes: NEWLINE, when enabled, sends a carriage-return line-feed at the end of the
command line. When disabled, only carriage return is sent.